A Method for Fast and Robust Intensity Based 2D/3D Registration in Differentiable Framework

This study introduces an innovative intensity-based registration method designed to align 3D image data volumes, such as Computed Tomography (CT), with 2D data, such as X-ray images, a crucial component of intra-operative navigation in image-guided surgery. Leveraging advanced autodifferentiable reconstruction techniques based on the GPU-accelerated Siddon algorithm, the proposed approach facilitates the generation of differentiable Digitally Reconstructed Radiographs (DRRs), enabling automatic image derivation according to its positional polar coordinates. Prior to the optimization process, an in-depth evaluation of the loss function landscape demonstrates its convex nature, revealing a global minimum aligning with the registered position of both datasets. Subsequently, various optimization algorithms, including Gradient Descent with Momentum, Gradient Descent with Damped Momentum, and Adam, undergo meticulous assessment for their efficacy in minimizing the registration loss function. Among these methods, Adam demonstrates particularly promising outcomes in terms of convergence rate and execution time. Furthermore, robustness evaluation through Monte Carlo simulations underscores the method’s remarkable ability to maintain registration accuracy even under perturbations. Despite inherent limitations related to DRR fidelity, such as the absence of reflection and scattering modeling, the proposed registration method achieves alignment. Robustness testing through Monte Carlo simulations, initializing positions at perturbed random locations, and applying the Adam optimization scheme, yields a convergence rate of 82.7%. The study outlines future research aimed at enhancing DRR fidelity through Monte Carlo simulations, refining registration accuracy, and expanding application to real anatomical parts. Overall, the proposed optimization strategies offer a compelling and versatile approach for rapid and precise 2/3D image registration in image-guided surgery, with significant potential for augmenting surgical precision and ultimately improving patient outcomes.

Authors

Publication Details

Journal
Journal of Computer Science
Published
2024-11-29
DOI
https://doi.org/10.3844/jcssp.2024.1593.1601
Primary Topic
Robotics and Sensor-Based Localization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Method for Fast and Robust Intensity Based 2D/3D Registration in Differentiable Framework

Arif Sasongko, Izzati Muhimmah, Agung Alfiansyah, Nanang Wiyono et al.
Journal of Computer Science
Robotics and Sensor-Based Localization
article

A Method for Fast and Robust Intensity Based 2D/3D Registration in Differentiable Framework

Arif Sasongko, Izzati Muhimmah, Agung Alfiansyah, Nanang Wiyono, Heru Sulastomo
article en

Abstract

This study introduces an innovative intensity-based registration method designed to align 3D image data volumes, such as Computed Tomography (CT), with 2D data, such as X-ray images, a crucial component of intra-operative navigation in image-guided surgery. Leveraging advanced autodifferentiable reconstruction techniques based on the GPU-accelerated Siddon algorithm, the proposed approach facilitates the generation of differentiable Digitally Reconstructed Radiographs (DRRs), enabling automatic image derivation according to its positional polar coordinates. Prior to the optimization process, an in-depth evaluation of the loss function landscape demonstrates its convex nature, revealing a global minimum aligning with the registered position of both datasets. Subsequently, various optimization algorithms, including Gradient Descent with Momentum, Gradient Descent with Damped Momentum, and Adam, undergo meticulous assessment for their efficacy in minimizing the registration loss function. Among these methods, Adam demonstrates particularly promising outcomes in terms of convergence rate and execution time. Furthermore, robustness evaluation through Monte Carlo simulations underscores the method’s remarkable ability to maintain registration accuracy even under perturbations. Despite inherent limitations related to DRR fidelity, such as the absence of reflection and scattering modeling, the proposed registration method achieves alignment. Robustness testing through Monte Carlo simulations, initializing positions at perturbed random locations, and applying the Adam optimization scheme, yields a convergence rate of 82.7%. The study outlines future research aimed at enhancing DRR fidelity through Monte Carlo simulations, refining registration accuracy, and expanding application to real anatomical parts. Overall, the proposed optimization strategies offer a compelling and versatile approach for rapid and precise 2/3D image registration in image-guided surgery, with significant potential for augmenting surgical precision and ultimately improving patient outcomes.

Journal of Computer ScienceVol. 20(12)
Climate action
Openalex Percentile: Top 65%
Robotics and Sensor-Based Localization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.