The Effectiveness of Cirtometry in the Assessment of Lung Expansion in Healthy Adults and Elderly: Scoping Review

Cirtometry is a low-cost and easy-to-handle technique that aims to quantitatively assess thoracoabdominal expansibility. Despite being commonly taught in undergraduate physiotherapy courses, there is no consensus on the standardization of the method, an essential factor that can affect reproducibility and the techniques used. The present study aims to evaluate the effectiveness of the cirtometry technique in the evaluation of pulmonary expansion in adults and the elderly. A Scoping Review was conducted. A search strategy was performed at Pubmed, Lilacs, PEDro and CAPES journal portal. Observational studies were included.The search strategies listed 949 articles, which after removing the duplicates and selection according to the eligibility requirements, totaled 8 articles. Of these, the majority (62.5%) was published in Brazil and all being in adults. The most used regions were axillary, xiphoid and umbilical and positioning in the orthostatic position. The values found were 4 to 7cm of expandability. Cirtometry is an accurate, reproducible and good quality technique for measuring thoracic mobility. However, consensus lacks that it is an accurate technique for providing data on lung volumes, normal values for adult and older adult statistics than on the degree of lung expansibility. Keywords: Lung Volume Measurements. Respiratory Mechanics. Respiratory Function Test Resumo A cirtometria é uma técnica de baixo custo e fácil manuseio que se propõem a avaliar quantitativamente a expansibilidade tóraco-abdominal. Apesar de ser comumente ensinada nos cursos de graduação em fisioterapia, não há consenso quanto a padronização do método, fator imprescindível que pode afetar a reprodutibilidade e confiabilidade da técnica. O presente estudo tem por objetivo avaliar a eficácia da técnica de cirtometria na avaliação da expansibilidade pulmonar em adultos e idosos saudáveis. Foi realizado um estudo de revisão de literatura do tipo Revisão de Escopo (Scoping Review). A estratégia de busca foi realizada na Pubmed, Lilacs, PEDro e portal de periódicos da Capes. Foram incluídos estudo observacionais. As estratégias de busca enumeraram 949 artigos, que após a retirada dos duplicados e seleção de acordo com os critérios de eligebilidade, somaram 8 artigos. Destes, a maioria (62,5%) foram publicados no Brasil e sendo todos em adultos. As regiões mais utilizadas foram axilar, xifoide e umbilical e o posicionamento na posição ortostática. Os valores encontrados foram de 4 a 7cm de expansibilidade. A cirtometria é uma técnica precisa, reprodutível e de boa confiabilidade para a mensuração da mobilidade torácica. No entanto, carece de consenso sobre ser uma técnica acurada para fornecer dados sobre os volumes pulmonares e os valores de normalidade para as populações adulta e idosa e sobre o grau de expansibilidade pulmonar. Palavras-chave: Medidas de Volume Pulmonar. Mecânica Respiratória. Testes de Função Respiratória.

Authors

Institutions

Publication Details

Journal
Journal of Health Sciences
Published
2024-11-21
DOI
https://doi.org/10.17921/2447-8938.2024v26n3p137-142
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effectiveness of Cirtometry in the Assessment of Lung Expansion in Healthy Adults and Elderly: Scoping Review

Maristela Prado e Silva Nazario, Ariane Hidalgo Mansano Pletsch, Gustavo De Conti Teixeira Costa, Thalia Francisca Martins et al.
Journal of Health Sciences
Chronic Obstructive Pulmonary Disease (COPD) Research
article

The Effectiveness of Cirtometry in the Assessment of Lung Expansion in Healthy Adults and Elderly: Scoping Review

Maristela Prado e Silva Nazario, Ariane Hidalgo Mansano Pletsch, Gustavo De Conti Teixeira Costa, Thalia Francisca Martins, Walkiria Shimoya-Bittencourt, Alfredo Cesín Vargas
article en

Abstract

Cirtometry is a low-cost and easy-to-handle technique that aims to quantitatively assess thoracoabdominal expansibility. Despite being commonly taught in undergraduate physiotherapy courses, there is no consensus on the standardization of the method, an essential factor that can affect reproducibility and the techniques used. The present study aims to evaluate the effectiveness of the cirtometry technique in the evaluation of pulmonary expansion in adults and the elderly. A Scoping Review was conducted. A search strategy was performed at Pubmed, Lilacs, PEDro and CAPES journal portal. Observational studies were included.The search strategies listed 949 articles, which after removing the duplicates and selection according to the eligibility requirements, totaled 8 articles. Of these, the majority (62.5%) was published in Brazil and all being in adults. The most used regions were axillary, xiphoid and umbilical and positioning in the orthostatic position. The values found were 4 to 7cm of expandability. Cirtometry is an accurate, reproducible and good quality technique for measuring thoracic mobility. However, consensus lacks that it is an accurate technique for providing data on lung volumes, normal values for adult and older adult statistics than on the degree of lung expansibility. Keywords: Lung Volume Measurements. Respiratory Mechanics. Respiratory Function Test Resumo A cirtometria é uma técnica de baixo custo e fácil manuseio que se propõem a avaliar quantitativamente a expansibilidade tóraco-abdominal. Apesar de ser comumente ensinada nos cursos de graduação em fisioterapia, não há consenso quanto a padronização do método, fator imprescindível que pode afetar a reprodutibilidade e confiabilidade da técnica. O presente estudo tem por objetivo avaliar a eficácia da técnica de cirtometria na avaliação da expansibilidade pulmonar em adultos e idosos saudáveis. Foi realizado um estudo de revisão de literatura do tipo Revisão de Escopo (Scoping Review). A estratégia de busca foi realizada na Pubmed, Lilacs, PEDro e portal de periódicos da Capes. Foram incluídos estudo observacionais. As estratégias de busca enumeraram 949 artigos, que após a retirada dos duplicados e seleção de acordo com os critérios de eligebilidade, somaram 8 artigos. Destes, a maioria (62,5%) foram publicados no Brasil e sendo todos em adultos. As regiões mais utilizadas foram axilar, xifoide e umbilical e o posicionamento na posição ortostática. Os valores encontrados foram de 4 a 7cm de expansibilidade. A cirtometria é uma técnica precisa, reprodutível e de boa confiabilidade para a mensuração da mobilidade torácica. No entanto, carece de consenso sobre ser uma técnica acurada para fornecer dados sobre os volumes pulmonares e os valores de normalidade para as populações adulta e idosa e sobre o grau de expansibilidade pulmonar. Palavras-chave: Medidas de Volume Pulmonar. Mecânica Respiratória. Testes de Função Respiratória.

Journal of Health SciencesVol. 26(3)
Universidade de Cuiabá (BR)
Good health and well-being
Openalex Percentile: Top 60%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.