Left ventricular pacing in a young African patient with a metallic tricuspid valve and infected epicardial leads: A case report

Tricuspid valve pathology is a relatively common anomaly. In patients with mechanical tricuspid valve replacement, implantation of a permanent pacemaker can be challenging due to the risk of valve damage, failure, and lead fracture associated with right ventricular endocardial leads. Epicardial leads may be an option, but they require a surgical procedure and are not preferred in patients with prior thoracotomy. This case report aims to demonstrate the safety and feasibility of left ventricular (LV) pacing via the coronary sinus (CS) in a 30-year-old young female with a mechanical tricuspid valve and infected epicardial leads. Due to the complications and contraindications of traditional approaches, Lead implantation via the CS was utilized. This method allowed for successful pacemaker implantation, demonstrating the feasibility and safety of LV pacing in such complex cases. The use of CS-guiding catheters and specialized leads facilitated effective cannulation and stable, reliable pacing, avoiding the need for further invasive surgeries.

Authors

Institutions

Publication Details

Journal
Journal of Postgraduate Medicine
Published
2024-10-01
DOI
https://doi.org/10.4103/jpgm.jpgm_283_24
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Left ventricular pacing in a young African patient with a metallic tricuspid valve and infected epicardial leads: A case report

Ameya Udyavar, Mukul Singhal
1 links
Journal of Postgraduate Medicine
Cardiac pacing and defibrillation studies
article

Left ventricular pacing in a young African patient with a metallic tricuspid valve and infected epicardial leads: A case report

Ameya Udyavar, Mukul Singhal
article en

Abstract

Tricuspid valve pathology is a relatively common anomaly. In patients with mechanical tricuspid valve replacement, implantation of a permanent pacemaker can be challenging due to the risk of valve damage, failure, and lead fracture associated with right ventricular endocardial leads. Epicardial leads may be an option, but they require a surgical procedure and are not preferred in patients with prior thoracotomy. This case report aims to demonstrate the safety and feasibility of left ventricular (LV) pacing via the coronary sinus (CS) in a 30-year-old young female with a mechanical tricuspid valve and infected epicardial leads. Due to the complications and contraindications of traditional approaches, Lead implantation via the CS was utilized. This method allowed for successful pacemaker implantation, demonstrating the feasibility and safety of LV pacing in such complex cases. The use of CS-guiding catheters and specialized leads facilitated effective cannulation and stable, reliable pacing, avoiding the need for further invasive surgeries.

Journal of Postgraduate MedicineVol. 70(4)
P. D. Hinduja Hospital and Medical Research Centre (IN)
Good health and well-being
Openalex Percentile: Top 60%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Left ventricular pacing in a young African patient with a metallic tricuspid valve and infected epicardial leads: A case report — Ameya Udyavar, Mukul Singhal · Journal of Postgraduate Medicine (2024) | TGRS Research Map | TGRS