Investigation on topology optimization of cold plate for battery thermal management based on phase change slurry

<p>Addressing the issue that single liquid cooling/air cooling technology cannot meet the thermal management requirements of the battery under high power conditions, the topology optimization of the cold plate for battery thermal management based on phase change slurry (PCS) is numerically studied in this paper. The mathematical model of topology optimization is constructed with multi-objectives of minimizing both the average temperature of the cold plate surface and the power consumption of the fluid flow based on the variable density method. The numerical results of the topology optimization cold plate (TCP) are then compared with those of the conventional rectangular channel cold plate (RCP). Moreover, the effects of the PCS mass concentration, weight coefficient, volume fraction of the fluid domain, inlet velocity of coolant, heat source power on the cooling performance and flow characteristics of the cold plate are analyzed. The results indicate that the reduction of average temperature, root mean square temperature and flow resistance factor of TCP achieves 23.9%, 80.8%, 18.2%, respectively, compared with RCP by using PCS with 20% mass concentration. The PCS demonstrates superior cooling performance compared to pure water, resulting in a more uniform temperature distribution across the cold plate. Overall, this study offers a novel outlook on topology optimization of the cold plate based on PCS, providing an attainable approach for improving the cooling capabilities while reducing the pump power consumption of battery thermal management system (BTMS).</p>

Authors

Publication Details

Journal
The Innovation Energy
Published
2024-11-29
DOI
https://doi.org/10.59717/j.xinn-energy.2024.100061
Citations
4
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on topology optimization of cold plate for battery thermal management based on phase change slurry

Rendong Shen, Guangliang Wang, Peilin Hou, Jun Zhao et al.
4 citations
The Innovation Energy
Advanced Battery Technologies Research
0.81
article

Investigation on topology optimization of cold plate for battery thermal management based on phase change slurry

Rendong Shen, Guangliang Wang, Peilin Hou, Jun Zhao, Fei Ma, Li Yang, Lei Gu, Jing Wang
article en
4 citations

Abstract

<p>Addressing the issue that single liquid cooling/air cooling technology cannot meet the thermal management requirements of the battery under high power conditions, the topology optimization of the cold plate for battery thermal management based on phase change slurry (PCS) is numerically studied in this paper. The mathematical model of topology optimization is constructed with multi-objectives of minimizing both the average temperature of the cold plate surface and the power consumption of the fluid flow based on the variable density method. The numerical results of the topology optimization cold plate (TCP) are then compared with those of the conventional rectangular channel cold plate (RCP). Moreover, the effects of the PCS mass concentration, weight coefficient, volume fraction of the fluid domain, inlet velocity of coolant, heat source power on the cooling performance and flow characteristics of the cold plate are analyzed. The results indicate that the reduction of average temperature, root mean square temperature and flow resistance factor of TCP achieves 23.9%, 80.8%, 18.2%, respectively, compared with RCP by using PCS with 20% mass concentration. The PCS demonstrates superior cooling performance compared to pure water, resulting in a more uniform temperature distribution across the cold plate. Overall, this study offers a novel outlook on topology optimization of the cold plate based on PCS, providing an attainable approach for improving the cooling capabilities while reducing the pump power consumption of battery thermal management system (BTMS).</p>

The Innovation EnergyVol. 2(1)
Openalex Percentile: Top 28%
Advanced Battery Technologies Research
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation on topology optimization of cold plate for battery thermal management based on phase change slurry — Rendong Shen, Guangliang Wang, et al. · The Innovation Energy (2024) | TGRS Research Map | TGRS