Daylight Optimization in Reading Spaces in the Design of Architecture Library, Kaduna State University, Nigeria

Daylight in a library is an intrinsic factor in teaching and learning spaces as daylight has been proven to stimulate the brain to stay active. However, too much daylight cause stress that affect assimilation. This study, therefore, examines and assesses the quality and quantity of daylight required for all learning spaces, according to International Energy Agency (IEA) using daylight elements to create variation in influx of lumen; with the purpose of combining manual and electronic study area. This case study is done Ahmadu Bello University, Zaria, Architecture Department Library using climate-based daylight modelling classification, in which Useful Daylight Illuminance (UDI) data are obtained from spaces with side lighting having daylight elements. Visual survey and quasi-experiment is done to test for the validity and reliability of the result, after which two daylight elements were introduced in the experiment and result taken intermediately. It is observed that the daylight performance metric of the Daylight Autonomy (DA) was influenced by the introduction of Daylight elements (DE) base on positioning and size of the windows and distance of the screen wall from the window opening. The combination of Centralised window (1100mm above floor level) and screen wall, 1200mm from the window opening resulted to 38.35% improvement in luminance. When centralised window (1100mm above floor level) was combined with screen wall at 900mm from the window opening, 36.76% improvement in interior luminance was recorded. The study shows that centralised window (1100mm above floor level) in combination with screen wall at 900mm is appropriate for redistributing light and improving luminance level in an interior space with other variable such as building orientation, window size, room reflectance, glazing type being the same. The readings from this research yielded a positive result and therefore were replicated in the design of the proposed faculty of architecture design in the Kaduna state University, Kaduna state.

Authors

Institutions

Publication Details

Journal
African Journal of Environmental Sciences and Renewable Energy
Published
2024-11-21
DOI
https://doi.org/10.62154/ajesre.2024.017.010488
Primary Topic
Architecture and Cultural Influences
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Daylight Optimization in Reading Spaces in the Design of Architecture Library, Kaduna State University, Nigeria

Aminu Umar, A.S. Elnafaty, Usman Bukar Wakawa, Sarkile Kawuwa Abubakar et al.
African Journal of Environmental Sciences and Renewable Energy
Architecture and Cultural Influences
article

Daylight Optimization in Reading Spaces in the Design of Architecture Library, Kaduna State University, Nigeria

Aminu Umar, A.S. Elnafaty, Usman Bukar Wakawa, Sarkile Kawuwa Abubakar, Usman Mohammad Bashir, Timon Duniya Timothy
article en

Abstract

Daylight in a library is an intrinsic factor in teaching and learning spaces as daylight has been proven to stimulate the brain to stay active. However, too much daylight cause stress that affect assimilation. This study, therefore, examines and assesses the quality and quantity of daylight required for all learning spaces, according to International Energy Agency (IEA) using daylight elements to create variation in influx of lumen; with the purpose of combining manual and electronic study area. This case study is done Ahmadu Bello University, Zaria, Architecture Department Library using climate-based daylight modelling classification, in which Useful Daylight Illuminance (UDI) data are obtained from spaces with side lighting having daylight elements. Visual survey and quasi-experiment is done to test for the validity and reliability of the result, after which two daylight elements were introduced in the experiment and result taken intermediately. It is observed that the daylight performance metric of the Daylight Autonomy (DA) was influenced by the introduction of Daylight elements (DE) base on positioning and size of the windows and distance of the screen wall from the window opening. The combination of Centralised window (1100mm above floor level) and screen wall, 1200mm from the window opening resulted to 38.35% improvement in luminance. When centralised window (1100mm above floor level) was combined with screen wall at 900mm from the window opening, 36.76% improvement in interior luminance was recorded. The study shows that centralised window (1100mm above floor level) in combination with screen wall at 900mm is appropriate for redistributing light and improving luminance level in an interior space with other variable such as building orientation, window size, room reflectance, glazing type being the same. The readings from this research yielded a positive result and therefore were replicated in the design of the proposed faculty of architecture design in the Kaduna state University, Kaduna state.

African Journal of Environmental Sciences and Renewable EnergyVol. 17(1)
Abubakar Tafawa Balewa University (NG)
Climate action
Openalex Percentile: Top 63%
Architecture and Cultural Influences
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.