Ultrahigh Resolving Power Ion Mobility Spectrometry with a Simple Pulser Circuitry

The pulsing circuitry for high resolving power drift-tube ion-mobility spectrometry is based on three avalanche photodiodes. These are switched on by illumination through optical fibers, which provide electrical insulation of the driver circuitry from the high voltage. The setup was tested with a series of quaternary ammonium ions introduced with an electrospray ion source. Two instruments with drift tubes of 10 and 30 cm length were employed and a separation voltage of up to 23.7 kV. Resolving powers above 200 could be achieved for the longer tube, which are comparable to those obtained with a previously employed more elaborate electrically floating pulser. The new pulser allows the creation of common two-state injection pulses as well as tristate pulses known to reduce the discrimination of low mobility ions. A comparison between the two pulsing regimes showed that, as predicted by theory, for the longer tube, the discrimination of low-mobility ions in the two-state shutter mode was less significant than for the shorter tube.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-29
DOI
https://doi.org/10.1021/acs.analchem.4c04881
Citations
1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrahigh Resolving Power Ion Mobility Spectrometry with a Simple Pulser Circuitry

Peter C. Hauser, Marc‐Aurèle Boillat
1 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
0.24
article

Ultrahigh Resolving Power Ion Mobility Spectrometry with a Simple Pulser Circuitry

Peter C. Hauser, Marc‐Aurèle Boillat
article en
1 citations

Abstract

The pulsing circuitry for high resolving power drift-tube ion-mobility spectrometry is based on three avalanche photodiodes. These are switched on by illumination through optical fibers, which provide electrical insulation of the driver circuitry from the high voltage. The setup was tested with a series of quaternary ammonium ions introduced with an electrospray ion source. Two instruments with drift tubes of 10 and 30 cm length were employed and a separation voltage of up to 23.7 kV. Resolving powers above 200 could be achieved for the longer tube, which are comparable to those obtained with a previously employed more elaborate electrically floating pulser. The new pulser allows the creation of common two-state injection pulses as well as tristate pulses known to reduce the discrimination of low mobility ions. A comparison between the two pulsing regimes showed that, as predicted by theory, for the longer tube, the discrimination of low-mobility ions in the two-state shutter mode was less significant than for the shorter tube.

Analytical ChemistryVol. 96(49)
University of Basel (CH)
Affordable and clean energy
Openalex Percentile: Top 47%
Mass Spectrometry Techniques and Applications
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.