Point-of-care detection of Japanese encephalitis virus based on advanced electrochemical immunosensor

Japanese encephalitis virus (JEV) causes acute inflammation of the brain affecting ∼68,000 annually in Asia. While conventional diagnostics like ELISA take days, this work developed an electrochemical immunosensor for rapid JEV detection at point-of-care. The sensor relied on carbon nanoparticles (CNPs) electrodeposited on screen-printed carbon electrodes (SPCE) and covalently linked with anti-JEV antibodies. Systematic optimization resulted in the optimal antibody concentration of 20 μg/mL with 30 min incubation enabling detection down to 42 fg/mL. The dynamic range spanned 100 fg/mL to 100 ng/mL within analysis time of 30 min. The SPCE-based disposable strip format provided < 8 % variability across electrodes. The CNP interface lowered detection limit by 10x versus earlier nanomaterial-assisted JEV sensors owing to high surface area and conductivity. Potential field deployment challenges include antibody stability for prolonged storage, validation across larger clinical cohorts, ease-of-use via integration with microfluidics/smartphones. Further robustification can enable rapid screening at point-of-care during outbreaks in resource-limited settings.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-11-29
DOI
https://doi.org/10.1016/j.ijoes.2024.100905
Citations
1
Primary Topic
Mosquito-borne diseases and control
Type
article
Field-Weighted Citation Impact
0.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Point-of-care detection of Japanese encephalitis virus based on advanced electrochemical immunosensor

Lijun Yue, Ping Wang
1 citations
International Journal of Electrochemical Science
Mosquito-borne diseases and control
0.54
article

Point-of-care detection of Japanese encephalitis virus based on advanced electrochemical immunosensor

Lijun Yue, Ping Wang
article en
1 citations

Abstract

Japanese encephalitis virus (JEV) causes acute inflammation of the brain affecting ∼68,000 annually in Asia. While conventional diagnostics like ELISA take days, this work developed an electrochemical immunosensor for rapid JEV detection at point-of-care. The sensor relied on carbon nanoparticles (CNPs) electrodeposited on screen-printed carbon electrodes (SPCE) and covalently linked with anti-JEV antibodies. Systematic optimization resulted in the optimal antibody concentration of 20 μg/mL with 30 min incubation enabling detection down to 42 fg/mL. The dynamic range spanned 100 fg/mL to 100 ng/mL within analysis time of 30 min. The SPCE-based disposable strip format provided < 8 % variability across electrodes. The CNP interface lowered detection limit by 10x versus earlier nanomaterial-assisted JEV sensors owing to high surface area and conductivity. Potential field deployment challenges include antibody stability for prolonged storage, validation across larger clinical cohorts, ease-of-use via integration with microfluidics/smartphones. Further robustification can enable rapid screening at point-of-care during outbreaks in resource-limited settings.

International Journal of Electrochemical ScienceVol. 20(1)
Jilin University (CN), Changchun University (CN)
Zero hunger
Openalex Percentile: Top 26%
Mosquito-borne diseases and control
0.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Point-of-care detection of Japanese encephalitis virus based on advanced electrochemical immunosensor — Lijun Yue, Ping Wang · International Journal of Electrochemical Science (2024) | TGRS Research Map | TGRS