Design of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods

<span>The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.</span>

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electrical Engineering and Computer Science
Published
2024-11-29
DOI
https://doi.org/10.11591/ijeecs.v37.i2.pp700-714
Citations
5
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods

Muldi Yuhendri, Nur Nabila Mohamed, Dedet Candra Riawan, Yulianta Siregar et al.
5 citations
Indonesian Journal of Electrical Engineering and Computer Science
Electric Motor Design and Analysis
1.04
article

Design of starting a three phase induction motor using direct on-line, variable frequency drive, soft starting, and auto transformer methods

Muldi Yuhendri, Nur Nabila Mohamed, Dedet Candra Riawan, Yulianta Siregar, Yosephine Rotua Oktaviana Siahaan
article en
5 citations

Abstract

<span>The problem with 3-phase induction motors is that when starting the motor, the motor starting current can reach five to seven times the nominal current. This research compares slip, starting current, bus voltage, acceleration torque, motor torque, energy savings, and kVAR from the direct on-line (DOL), variable frequency drive (VFD), soft starting, and autotransformer starting methods in the electrical transient analyzer program (ETAP) software. This research result shows that the fastest VFD slip reaches a steady state, namely at 11+ seconds. The lowest starting/starting current is owned by the VFD method, namely <20% full load amps (FLA) in the first 2 seconds. The lowest decrease in bus voltage at steady state was experienced by the VFD method, namely 0.8152%. The quickest acceleration torque reaches a steady state in the VFD method, namely in 11+ seconds. The soft starting method owns the lowest starting torque, namely 20.75%. The soft starting method has the largest energy savings, namely 148.02 kW. Of the several variables observed, the best starting method is the VFD method.</span>

Indonesian Journal of Electrical Engineering and Computer ScienceVol. 37(2)
Sepuluh Nopember Institute of Technology (ID), State University of Padang (ID), Universitas Sumatera Utara (ID)
Affordable and clean energy
Openalex Percentile: Top 22%
Electric Motor Design and Analysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.