A Cap-less LDO Regulator with Improved Load Regulation using Adaptive Feedback Control and Modified Voltage Damper

This paper proposes a cap-less low-dropout (LDO) regulator using the Adaptive feedback control and the modified Voltage damper with the dual power transistors. To enhance the current efficiency, the main power transistor and the related low-impedance (LI) buffer are turned off by the Adaptive feedback control circuit and the Switch circuit to save the power at the light load. In addition, the modified Voltage damper is used to improve the undershoot transient response without extra static current. The proposed design is fabricated using a typical 0.18 µm CMOS process. The quiescent current is decreased to 18.32 μA. The peak current efficiency is simulated to be 99.97% with the load regulation of 0.082 mV/mA.

Authors

Institutions

Publication Details

Published
2024-08-19
DOI
https://doi.org/10.1109/isocc62682.2024.10762076
Primary Topic
Sensorless Control of Electric Motors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Cap-less LDO Regulator with Improved Load Regulation using Adaptive Feedback Control and Modified Voltage Damper

Tzung-Je Lee, H.Y. Chiu
Sensorless Control of Electric Motors
article

A Cap-less LDO Regulator with Improved Load Regulation using Adaptive Feedback Control and Modified Voltage Damper

Tzung-Je Lee, H.Y. Chiu
article en

Abstract

This paper proposes a cap-less low-dropout (LDO) regulator using the Adaptive feedback control and the modified Voltage damper with the dual power transistors. To enhance the current efficiency, the main power transistor and the related low-impedance (LI) buffer are turned off by the Adaptive feedback control circuit and the Switch circuit to save the power at the light load. In addition, the modified Voltage damper is used to improve the undershoot transient response without extra static current. The proposed design is fabricated using a typical 0.18 µm CMOS process. The quiescent current is decreased to 18.32 μA. The peak current efficiency is simulated to be 99.97% with the load regulation of 0.082 mV/mA.

National Sun Yat-sen University (TW)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 81%
Sensorless Control of Electric Motors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.