Design and Simulation of an OTA for ECG Signals with High PSRR and CMRR

This paper presents the design and simulation of a high-gain, two-stage OTA. Using a 180 nm standard CMOS technology and resistive approximation techniques. The proposed symmetrical OTA, designed to function in the strong inversion region, achieves a gain of 72.06 dB, PSRR<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup>, PSRR<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-</sup> of 108 dB and 114 dB respectively, CMRR of 95 dB and a bandwidth of 22.9 kHz. Additionally, an IRN of 0.93 µVrms is obtained. Simulation results indicate that the designed OTA is a highly suitable candidate for biomedical applications, particularly for the detection and monitoring of electrocardiographic (ECG) signals.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/icev63254.2024.10765992
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Simulation of an OTA for ECG Signals with High PSRR and CMRR

F. Sandoval‐Ibarra, Francisco López-Huerta, Aurora M. Castilla, R. M. Woo-García et al.
ECG Monitoring and Analysis
article

Design and Simulation of an OTA for ECG Signals with High PSRR and CMRR

F. Sandoval‐Ibarra, Francisco López-Huerta, Aurora M. Castilla, R. M. Woo-García, J. Martínez-Castillo
article en

Abstract

This paper presents the design and simulation of a high-gain, two-stage OTA. Using a 180 nm standard CMOS technology and resistive approximation techniques. The proposed symmetrical OTA, designed to function in the strong inversion region, achieves a gain of 72.06 dB, PSRR<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">+</sup>, PSRR<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-</sup> of 108 dB and 114 dB respectively, CMRR of 95 dB and a bandwidth of 22.9 kHz. Additionally, an IRN of 0.93 µVrms is obtained. Simulation results indicate that the designed OTA is a highly suitable candidate for biomedical applications, particularly for the detection and monitoring of electrocardiographic (ECG) signals.

Universidad Veracruzana (MX), Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (MX)
Universidad Veracruzana
Affordable and clean energy
Openalex Percentile: Top 60%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Simulation of an OTA for ECG Signals with High PSRR and CMRR — F. Sandoval‐Ibarra, Francisco López-Huerta, et al. · (2024) | TGRS Research Map | TGRS