Changes in Ventricular Repolarization After Right Ventricular and Left Bundle Branch Pacing

Left bundle branch pacing (LBBP) has recently emerged as an alternative to the widely used right ventricular pacing (RVP), which presents limitations related to the induced ventricular activation dyssynchrony. Here, we measured the QRS complex duration (QRSd) and an index of sympathetic modulation of ventricular repolarization, called Periodic Repolarization Dynamics (PRD), one day and one year after pacemaker implantation. In our cohort of patients with right and left bundle branch block, LBBP induced a decrease in QRSd (median [IQR] at baseline: $\mathbf{1 6 0. 5}$ [20.20] ms, after one day: 133.5 [25.25], after one year: $133[23.8] \mathrm{ms}$), thus indicating higher activation synchronization. On the other hand, RVP showed no significant changes (155.0 [15.15], 156. 5 [30.30] and 150.5 [34.34] ms). PRD was reduced after one-day pacing for both LBBP and RVP, but returned to baseline values after one year. In conclusion, LBBP shows improved activation synchronization as compared to RVP, with no significant differences in sympathetically-mediated repolarization oscillations between the two pacing techniques.

Authors

Institutions

Publication Details

Published
2024-10-23
DOI
https://doi.org/10.1109/esgco63003.2024.10767030
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Changes in Ventricular Repolarization After Right Ventricular and Left Bundle Branch Pacing

Ana Mincholé, Javier Ramos, Esther Pueyo, Clara Sales et al.
Cardiac pacing and defibrillation studies
article

Changes in Ventricular Repolarization After Right Ventricular and Left Bundle Branch Pacing

Ana Mincholé, Javier Ramos, Esther Pueyo, Clara Sales, Jorge Melero, Juan Pablo Martí­nez, Mercedes Cabrera, Saúl Palacios
article en

Abstract

Left bundle branch pacing (LBBP) has recently emerged as an alternative to the widely used right ventricular pacing (RVP), which presents limitations related to the induced ventricular activation dyssynchrony. Here, we measured the QRS complex duration (QRSd) and an index of sympathetic modulation of ventricular repolarization, called Periodic Repolarization Dynamics (PRD), one day and one year after pacemaker implantation. In our cohort of patients with right and left bundle branch block, LBBP induced a decrease in QRSd (median [IQR] at baseline: $\mathbf{1 6 0. 5}$ [20.20] ms, after one day: 133.5 [25.25], after one year: $133[23.8] \mathrm{ms}$), thus indicating higher activation synchronization. On the other hand, RVP showed no significant changes (155.0 [15.15], 156. 5 [30.30] and 150.5 [34.34] ms). PRD was reduced after one-day pacing for both LBBP and RVP, but returned to baseline values after one year. In conclusion, LBBP shows improved activation synchronization as compared to RVP, with no significant differences in sympathetically-mediated repolarization oscillations between the two pacing techniques.

Universidad de Zaragoza (ES), Hospital Clínico Universitario Lozano Blesa (ES)
Ministerio de Ciencia e Innovación
Zero hunger
Openalex Percentile: Top 60%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Changes in Ventricular Repolarization After Right Ventricular and Left Bundle Branch Pacing — Ana Mincholé, Javier Ramos, et al. · (2024) | TGRS Research Map | TGRS