Evaluation of Wear on Copper Pipes Deposited in Different Environments: An Understanding of Damage in Geothermal Heat Exchangers

This study presents the evaluation and comparison of damage in samples of commercial copper pipes exposed to different environments: atmospheric conditions, underground, seawater, and river water. These environments were selected to contrast the alterations in outer diameter and thickness that pipes used in geothermal heat exchangers may undergo. The exposure period for the samples was 155 days, with results measured experimentally and analyzed statistically. The findings indicate that the samples exposed to seawater and underground conditions exhibit the greatest reductions in outer diameter and thickness, respectively, while the sample exposed to atmospheric conditions does not show a significant damage rate.

Authors

Institutions

Publication Details

Published
2024-10-21
DOI
https://doi.org/10.1109/icev63254.2024.10765937
Citations
1
Primary Topic
Metal Alloys Wear and Properties
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Wear on Copper Pipes Deposited in Different Environments: An Understanding of Damage in Geothermal Heat Exchangers

César Ramírez-Dolores, Jorge Andaverde, Virginia Arias-Márquez, Daniel Ramón López-Liévano et al.
1 citations
Metal Alloys Wear and Properties
0.12
article

Evaluation of Wear on Copper Pipes Deposited in Different Environments: An Understanding of Damage in Geothermal Heat Exchangers

César Ramírez-Dolores, Jorge Andaverde, Virginia Arias-Márquez, Daniel Ramón López-Liévano, Ricardo Castillo-Bribiesca
article en
1 citations

Abstract

This study presents the evaluation and comparison of damage in samples of commercial copper pipes exposed to different environments: atmospheric conditions, underground, seawater, and river water. These environments were selected to contrast the alterations in outer diameter and thickness that pipes used in geothermal heat exchangers may undergo. The exposure period for the samples was 155 days, with results measured experimentally and analyzed statistically. The findings indicate that the samples exposed to seawater and underground conditions exhibit the greatest reductions in outer diameter and thickness, respectively, while the sample exposed to atmospheric conditions does not show a significant damage rate.

Universidad Veracruzana (MX), Universidad de Sotavento (MX)
Openalex Percentile: Top 58%
Metal Alloys Wear and Properties
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Wear on Copper Pipes Deposited in Different Environments: An Understanding of Damage in Geothermal Heat Exchangers — César Ramírez-Dolores, Jorge Andaverde, et al. · (2024) | TGRS Research Map | TGRS