Evaluation of Wear on Copper Pipes Deposited in Different Environments: An Understanding of Damage in Geothermal Heat Exchangers
This study presents the evaluation and comparison of damage in samples of commercial copper pipes exposed to different environments: atmospheric conditions, underground, seawater, and river water. These environments were selected to contrast the alterations in outer diameter and thickness that pipes used in geothermal heat exchangers may undergo. The exposure period for the samples was 155 days, with results measured experimentally and analyzed statistically. The findings indicate that the samples exposed to seawater and underground conditions exhibit the greatest reductions in outer diameter and thickness, respectively, while the sample exposed to atmospheric conditions does not show a significant damage rate.
Authors
- César Ramírez-Dolores (ORCID: https://orcid.org/0000-0002-4817-6254)
- Jorge Andaverde (ORCID: https://orcid.org/0000-0002-6385-9598)
- Virginia Arias-Márquez
- Daniel Ramón López-Liévano
- Ricardo Castillo-Bribiesca
Institutions
- Universidad Veracruzana (MX)
- Universidad de Sotavento (MX)
Publication Details
- Published
- 2024-10-21
- DOI
- https://doi.org/10.1109/icev63254.2024.10765937
- Citations
- 1
- Primary Topic
- Metal Alloys Wear and Properties
- Type
- article
- Field-Weighted Citation Impact
- 0.12