An Integrator Time-Constant Calibration Scheme with Modified Voltage to Digital Converter

This paper presents a time-constant calibration technique with a modified differential 10-bit voltage-to-digital converter. The VDC utilizes a counting-based approach and includes an automatic offset calibration comparator. The comparator performs calibration by controlling the number of compensating MOS transistors connected to the primary input pair. It ensures that the VDC avoids digital code conversion errors caused by MOS mismatch in the comparator. The measured linearity of the VDC is evaluated by linear regression with an R-squared value of 0.9993. Also, the simulation of the time-constant calibration scheme shows the correct calibration result, which indicates the proposed scheme can gain a time-constant error of around 1% from the initial error of ±20%.

Authors

Institutions

Publication Details

Published
2024-08-19
DOI
https://doi.org/10.1109/isocc62682.2024.10762266
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Integrator Time-Constant Calibration Scheme with Modified Voltage to Digital Converter

Yin-Qin Ye, Hsiao-Hsing Chou, Hsin‐Liang Chen, Jen‐Shiun Chiang et al.
Sensor Technology and Measurement Systems
article

An Integrator Time-Constant Calibration Scheme with Modified Voltage to Digital Converter

Yin-Qin Ye, Hsiao-Hsing Chou, Hsin‐Liang Chen, Jen‐Shiun Chiang, Ting-Yu Syu
article en

Abstract

This paper presents a time-constant calibration technique with a modified differential 10-bit voltage-to-digital converter. The VDC utilizes a counting-based approach and includes an automatic offset calibration comparator. The comparator performs calibration by controlling the number of compensating MOS transistors connected to the primary input pair. It ensures that the VDC avoids digital code conversion errors caused by MOS mismatch in the comparator. The measured linearity of the VDC is evaluated by linear regression with an R-squared value of 0.9993. Also, the simulation of the time-constant calibration scheme shows the correct calibration result, which indicates the proposed scheme can gain a time-constant error of around 1% from the initial error of ±20%.

Tamkang University (TW), National Taichung University of Science and Technology (TW)
National Science and Technology Council
Affordable and clean energy
Openalex Percentile: Top 75%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.