Development of a comprehensive simulation to explore the energy-saving and daylighting features of a multifunctional window in tropical climates

• Energy and daylighting performance assessment of a novel multifunctional window. • MFWs provide electricity and heat, along with reducing the building’s cooling load. • CFD and daylighting tools model an office with MFW for comprehensive analysis. • Using MFWs, south-facing orientations offer net electricity savings of 33 % to 75 %. • Fenestrations with 50 % PV coverage achieve the balance between daylighting levels and energy generation . Leveraging the entire solar spectrum in building facades is crucial to achieving zero-energy buildings concept. This study presents a novel multifunctional window (MFW) that combines photovoltaic laminates with a selective liquid filter (SLF) in a mono-glazing system. For a comprehensive assessment of the energy and daylight performance of a standard office equipped with MFW, it has been developed an innovative model integrating thermal, electrical, optical, and energy aspects, utilizing both CFD and daylighting analysis tools. The net electricity benefit (NEB) serves as a key metric to evaluate the energy performance of MFWs compared to traditional windows. Additionally, Useful Daylight Illuminance (UDI), Illuminance Uniformity (U o ), and Daylight Glare Probability (DGP) are employed to predict the annual daylight performance of MFW under various Photovoltaic-to-Space Ratios (PVSR). The findings reveal that using MFWs significantly reduces office cooling energy consumption, ranging from 41 % to 73 % in south-oriented buildings compared to standard glazing. Despite increased artificial lighting consumption (ALC) with PVSR, MFWs significantly improve the NEB due to higher energy generation and reduced cooling loads. MFWs with 50 % PVSR also enhance daylight distribution uniformity and minimize potential glare, while balancing PVSR at 50 % optimizes energy generation and ensures ample illumination in office spaces. Further, the levelized cost of electricity generation (LCOE el ) for the MFW ranges from $0.166 to $0.143/kWh e .

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2024-11-29
DOI
https://doi.org/10.1016/j.enconman.2024.119325
Citations
7
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a comprehensive simulation to explore the energy-saving and daylighting features of a multifunctional window in tropical climates

Mostafa M. Abdelsamie, Yue Yang, Jianhui Liu, Mohamed I. Hassan Ali et al.
7 citations
Energy Conversion and Management
Building Energy and Comfort Optimization
1.86
article

Development of a comprehensive simulation to explore the energy-saving and daylighting features of a multifunctional window in tropical climates

Mostafa M. Abdelsamie, Yue Yang, Jianhui Liu, Mohamed I. Hassan Ali, Luling Li, Mohamed Fayed
article en
7 citations

Abstract

• Energy and daylighting performance assessment of a novel multifunctional window. • MFWs provide electricity and heat, along with reducing the building’s cooling load. • CFD and daylighting tools model an office with MFW for comprehensive analysis. • Using MFWs, south-facing orientations offer net electricity savings of 33 % to 75 %. • Fenestrations with 50 % PV coverage achieve the balance between daylighting levels and energy generation . Leveraging the entire solar spectrum in building facades is crucial to achieving zero-energy buildings concept. This study presents a novel multifunctional window (MFW) that combines photovoltaic laminates with a selective liquid filter (SLF) in a mono-glazing system. For a comprehensive assessment of the energy and daylight performance of a standard office equipped with MFW, it has been developed an innovative model integrating thermal, electrical, optical, and energy aspects, utilizing both CFD and daylighting analysis tools. The net electricity benefit (NEB) serves as a key metric to evaluate the energy performance of MFWs compared to traditional windows. Additionally, Useful Daylight Illuminance (UDI), Illuminance Uniformity (U o ), and Daylight Glare Probability (DGP) are employed to predict the annual daylight performance of MFW under various Photovoltaic-to-Space Ratios (PVSR). The findings reveal that using MFWs significantly reduces office cooling energy consumption, ranging from 41 % to 73 % in south-oriented buildings compared to standard glazing. Despite increased artificial lighting consumption (ALC) with PVSR, MFWs significantly improve the NEB due to higher energy generation and reduced cooling loads. MFWs with 50 % PVSR also enhance daylight distribution uniformity and minimize potential glare, while balancing PVSR at 50 % optimizes energy generation and ensures ample illumination in office spaces. Further, the levelized cost of electricity generation (LCOE el ) for the MFW ranges from $0.166 to $0.143/kWh e .

Energy Conversion and ManagementVol. 325
Khalifa University of Science and Technology (AE), Harbin Institute of Technology (CN), Helwan University (EG)
Climate action
Openalex Percentile: Top 15%
Building Energy and Comfort Optimization
1.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.