Low-Consumption and High-Efficiency Isotope Analysis by Microultrasonic Single-Droplet Nebulization Sampling Multicollector Inductively Coupled Plasma Mass Spectrometry

Metal stable isotopes are increasingly applied in various fields, including planetary science and medical research, highlighting the need for isotope analysis methods capable of handling precious and microvolume samples. This study introduces a novel, low-consumption, high-efficiency isotope analysis method using MC-ICP-MS based on microultrasonic single-droplet nebulization (MUSDN). The proposed MUSDN enables the complete nebulization of microliter-sized droplets, delivering high-sensitivity transient analytical signals with a duration of several seconds. Under optimized conditions, MUSDN exhibited significantly enhanced sensitivity compared to conventional pneumatic nebulization, achieving 17-fold and 12-fold improvements for <sup>7</sup>Li and <sup>63</sup>Cu, respectively. The achieved external precisions (2SD) for δ<sup>7</sup>Li and δ<sup>65</sup>Cu were 0.3 and 0.08‰, with single analysis consuming only 1 ng of Li and 2 ng of Cu, respectively. This represents a reduction in sample consumption by 1-2 orders of magnitude compared to conventional PN-MC-ICP-MS while also improving the analysis speed by at least 10-fold due to rapid residual washout. Furthermore, our method demonstrated superior δ<sup>65</sup>Cu analytical precision compared to other high-sensitivity transient analysis methods (0.19‰ with a laser ablation system) with similar sample consumption. Finally, the accuracy of the proposed method was validated through the analysis of geological CRMs, serum CRMs, in-house standard samples, and a series of real serum samples. This novel isotope analysis method provides a promising approach for isotope applications involving precious and microvolume samples.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-29
DOI
https://doi.org/10.1021/acs.analchem.4c04312
Citations
7
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-Consumption and High-Efficiency Isotope Analysis by Microultrasonic Single-Droplet Nebulization Sampling Multicollector Inductively Coupled Plasma Mass Spectrometry

Zhenli Zhu, Junhang Dong, Pengju Xing, Guan Wang et al.
7 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
1.69
article

Low-Consumption and High-Efficiency Isotope Analysis by Microultrasonic Single-Droplet Nebulization Sampling Multicollector Inductively Coupled Plasma Mass Spectrometry

Zhenli Zhu, Junhang Dong, Pengju Xing, Guan Wang, Zhi‐Qi Dai, Linjie Chen, Xing Liu, Shuyang Li, Yang Yu, Hongtao Zheng
article en
7 citations

Abstract

Metal stable isotopes are increasingly applied in various fields, including planetary science and medical research, highlighting the need for isotope analysis methods capable of handling precious and microvolume samples. This study introduces a novel, low-consumption, high-efficiency isotope analysis method using MC-ICP-MS based on microultrasonic single-droplet nebulization (MUSDN). The proposed MUSDN enables the complete nebulization of microliter-sized droplets, delivering high-sensitivity transient analytical signals with a duration of several seconds. Under optimized conditions, MUSDN exhibited significantly enhanced sensitivity compared to conventional pneumatic nebulization, achieving 17-fold and 12-fold improvements for <sup>7</sup>Li and <sup>63</sup>Cu, respectively. The achieved external precisions (2SD) for δ<sup>7</sup>Li and δ<sup>65</sup>Cu were 0.3 and 0.08‰, with single analysis consuming only 1 ng of Li and 2 ng of Cu, respectively. This represents a reduction in sample consumption by 1-2 orders of magnitude compared to conventional PN-MC-ICP-MS while also improving the analysis speed by at least 10-fold due to rapid residual washout. Furthermore, our method demonstrated superior δ<sup>65</sup>Cu analytical precision compared to other high-sensitivity transient analysis methods (0.19‰ with a laser ablation system) with similar sample consumption. Finally, the accuracy of the proposed method was validated through the analysis of geological CRMs, serum CRMs, in-house standard samples, and a series of real serum samples. This novel isotope analysis method provides a promising approach for isotope applications involving precious and microvolume samples.

Analytical ChemistryVol. 96(50)
China University of Geosciences (CN), State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering (CN)
Affordable and clean energy
Openalex Percentile: Top 16%
Mass Spectrometry Techniques and Applications
1.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.