Assessment Of Complex Ii Fuel Oil Heat Exchanger Utilizing Heat Transfer Methodology

The heating stage of oil and gas refining commences with a heat exchanger. Using the pressure drop method and dirt factor in conjunction with the utmost standard permissible limit is one method of evaluating the thermal efficiency of a heat exchanger. This is performed to ascertain the value of the pressure drop, or pressure drop, which is directed at the fluid passage in the shell and pipeline. Moreover, a dust factor value is necessary to account for the potential accumulation of impurities and scale on the walls outside the heat exchanger conduit. The dust factor value is the maximum value that the parameter permits to ascertain the feasibility of the heat exchanger. Heat Exchanger 011-E-112 in the Fuel Oil Complex Unit The results indicate that heat exchanger 11E-112 can still be utilized despite the necessity for design enhancements. The design data for the shell is 1.7 psi, and the tube is approximately 18.92 psi. The Dirt Factor values for the shell and tube are 0.017 BTU/hour ft2°F and 0.034 BTU/hour ft2°F, respectively. The tube pressure drop value is 130.32 psi, while the shell pressure drop value is 2.53 psi.

Authors

Institutions

Publication Details

Journal
International Journal Of Science Technology & Management
Published
2024-11-27
DOI
https://doi.org/10.46729/ijstm.v5i6.1194
Primary Topic
Heat transfer and supercritical fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment Of Complex Ii Fuel Oil Heat Exchanger Utilizing Heat Transfer Methodology

Budi Nugroho, Griselda Ivonne Aqilah, Nimrod Alvino
International Journal Of Science Technology & Management
Heat transfer and supercritical fluids
article

Assessment Of Complex Ii Fuel Oil Heat Exchanger Utilizing Heat Transfer Methodology

Budi Nugroho, Griselda Ivonne Aqilah, Nimrod Alvino
article en

Abstract

The heating stage of oil and gas refining commences with a heat exchanger. Using the pressure drop method and dirt factor in conjunction with the utmost standard permissible limit is one method of evaluating the thermal efficiency of a heat exchanger. This is performed to ascertain the value of the pressure drop, or pressure drop, which is directed at the fluid passage in the shell and pipeline. Moreover, a dust factor value is necessary to account for the potential accumulation of impurities and scale on the walls outside the heat exchanger conduit. The dust factor value is the maximum value that the parameter permits to ascertain the feasibility of the heat exchanger. Heat Exchanger 011-E-112 in the Fuel Oil Complex Unit The results indicate that heat exchanger 11E-112 can still be utilized despite the necessity for design enhancements. The design data for the shell is 1.7 psi, and the tube is approximately 18.92 psi. The Dirt Factor values for the shell and tube are 0.017 BTU/hour ft2°F and 0.034 BTU/hour ft2°F, respectively. The tube pressure drop value is 130.32 psi, while the shell pressure drop value is 2.53 psi.

International Journal Of Science Technology & ManagementVol. 5(6)
Oil and Gas Center (CN), CPCL Polytechnic College (IN)
Affordable and clean energy
Openalex Percentile: Top 76%
Heat transfer and supercritical fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.