Study on the dynamics of radon concentration buildup in the closed-loop measurement system with RAD7 online radon monitor

Radon and thoron exhalation rates from samples are estimated by the standard closed-loop technique using online radon monitors. Conventionally, the mass balance equation is formulated by considering the closed air volume of the sample chamber and the detector chamber put together. This model serves the purpose of estimating the radon/thoron exhalation rates for the prescribed pump flow rate of 1 L min-1 using RAD7 online monitor. The flow rate requirement is crucial for thoron measurement due to its short half-life. In the present work, an alternate model is proposed which simulates the dynamics of radon/thoron concentration dictated by the air entry and exit rate and brings out the effect of pump flow rate. This model is more of academic interest, where sample chamber and detector chamber are considered as two separate entities since they are separated by tubing. The mass balance equation is reformulated considering the air entry and exit in and out the individual chambers. The radon buildup in the sample chamber and detector chamber were treated separately by two coupled differential equations. The equations were numerically solved. The model reiterated the fact that the lower flow rates do not affect the buildup profile of relatively long-lived 222Rn (half-life 3.8 d) and its steady-state concentration attained in the closed air volume. However, experiments carried out for flow rates 0.3 and 0.5 L min-1 with RAD7 monitor using powdered granite sample with higher 226Ra and 232Th concentrations gave contradicting results. The radon effective removal rate was found to decrease with increase in flow rate from 0.3 to 1 L min-1. This issue was investigated, and it was speculated that the thoron interference problem might not be properly addressed for flow rates <1 L min-1. This was ascertained by observing the effective radon removal rate in the absence of thoron by conducting radon decay experiments with different flow rates. For the case of short-lived thoron (half-life 55 s), the model described the dynamics of thoron concentration in the closed loop and the steady-state concentrations attained in the detector and sample chamber. As expected, the model showed that due to decay losses during transit of thoron between the chambers, the steady-state concentrations attained in the chambers considerably differ from each other even for 1 L min-1 flow rate.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-28
DOI
https://doi.org/10.1093/rpd/ncae225
Citations
3
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the dynamics of radon concentration buildup in the closed-loop measurement system with RAD7 online radon monitor

N. Chitra, Venkata Srinivas Challa, Chandrasekaran Seethapathy, Balasubramaniam Venkatraman
3 citations
Radiation Protection Dosimetry
Radioactivity and Radon Measurements
1.35
article

Study on the dynamics of radon concentration buildup in the closed-loop measurement system with RAD7 online radon monitor

N. Chitra, Venkata Srinivas Challa, Chandrasekaran Seethapathy, Balasubramaniam Venkatraman
article en
3 citations

Abstract

Radon and thoron exhalation rates from samples are estimated by the standard closed-loop technique using online radon monitors. Conventionally, the mass balance equation is formulated by considering the closed air volume of the sample chamber and the detector chamber put together. This model serves the purpose of estimating the radon/thoron exhalation rates for the prescribed pump flow rate of 1 L min-1 using RAD7 online monitor. The flow rate requirement is crucial for thoron measurement due to its short half-life. In the present work, an alternate model is proposed which simulates the dynamics of radon/thoron concentration dictated by the air entry and exit rate and brings out the effect of pump flow rate. This model is more of academic interest, where sample chamber and detector chamber are considered as two separate entities since they are separated by tubing. The mass balance equation is reformulated considering the air entry and exit in and out the individual chambers. The radon buildup in the sample chamber and detector chamber were treated separately by two coupled differential equations. The equations were numerically solved. The model reiterated the fact that the lower flow rates do not affect the buildup profile of relatively long-lived 222Rn (half-life 3.8 d) and its steady-state concentration attained in the closed air volume. However, experiments carried out for flow rates 0.3 and 0.5 L min-1 with RAD7 monitor using powdered granite sample with higher 226Ra and 232Th concentrations gave contradicting results. The radon effective removal rate was found to decrease with increase in flow rate from 0.3 to 1 L min-1. This issue was investigated, and it was speculated that the thoron interference problem might not be properly addressed for flow rates <1 L min-1. This was ascertained by observing the effective radon removal rate in the absence of thoron by conducting radon decay experiments with different flow rates. For the case of short-lived thoron (half-life 55 s), the model described the dynamics of thoron concentration in the closed loop and the steady-state concentrations attained in the detector and sample chamber. As expected, the model showed that due to decay losses during transit of thoron between the chambers, the steady-state concentrations attained in the chambers considerably differ from each other even for 1 L min-1 flow rate.

Radiation Protection DosimetryVol. 201(1)
Indira Gandhi Centre for Atomic Research (IN)
Clean water and sanitation
Openalex Percentile: Top 18%
Radioactivity and Radon Measurements
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.