Some aspects of concentrating infrared radiation

The paper presents studies related to the creation of an effective concentrator of infrared radiation. Using such concentrators, it will be possible to detect weak or long-distance infrared radiation. According to the authors, in this case, the use of concentrators with reflective surfaces is preferable to lens concentrators. In particular, a phocone design is proposed, which consists of several sections. Each section is an independent phocone and focuses the rays incident on it by a single reflection. The phocone of the above design was tested and its efficiency was compared with a conventional conical phocone with the same concentration quality. The initial results of the experiment showed that its efficiency was higher. In addition, the dimensions (length) of the concentrator were significantly reduced.

Authors

Institutions

Publication Details

Journal
GEORGIAN SCIENTISTS
Published
2024-11-28
DOI
https://doi.org/10.52340/gs.2024.06.04.26
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Some aspects of concentrating infrared radiation

Tengiz Khachidze, Nikoloz Khachidze
GEORGIAN SCIENTISTS
Calibration and Measurement Techniques
article

Some aspects of concentrating infrared radiation

Tengiz Khachidze, Nikoloz Khachidze
article en

Abstract

The paper presents studies related to the creation of an effective concentrator of infrared radiation. Using such concentrators, it will be possible to detect weak or long-distance infrared radiation. According to the authors, in this case, the use of concentrators with reflective surfaces is preferable to lens concentrators. In particular, a phocone design is proposed, which consists of several sections. Each section is an independent phocone and focuses the rays incident on it by a single reflection. The phocone of the above design was tested and its efficiency was compared with a conventional conical phocone with the same concentration quality. The initial results of the experiment showed that its efficiency was higher. In addition, the dimensions (length) of the concentrator were significantly reduced.

GEORGIAN SCIENTISTS
Optica (US)
Openalex Percentile: Top 65%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.