Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelves

The S1 body diagonal is consistently located anterior to the S1 recess in lateral fluoroscopic projections, providing a potential safe corridor for transiliac-transsacral screw placement at the S1 level in nondysmorphic pelves. Further research is needed to confirm these findings with CT imaging and evaluate the technical feasibility of screw placement.

Authors

Institutions

Publication Details

Journal
European Journal of Orthopaedic Surgery & Traumatology
Published
2024-11-28
DOI
https://doi.org/10.1007/s00590-024-04157-5
Citations
1
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelves

Jan Gewiess, Christoph E. Albers, Sven Hoppe, Christian Tinner et al.
1 citations
European Journal of Orthopaedic Surgery & Traumatology
Pelvic and Acetabular Injuries
0.57
article

Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelves

Jan Gewiess, Christoph E. Albers, Sven Hoppe, Christian Tinner, Fabian Cedric Aregger, Moritz C. Deml, S.F. Schaible
article en
1 citations

Abstract

The S1 body diagonal is consistently located anterior to the S1 recess in lateral fluoroscopic projections, providing a potential safe corridor for transiliac-transsacral screw placement at the S1 level in nondysmorphic pelves. Further research is needed to confirm these findings with CT imaging and evaluate the technical feasibility of screw placement.

European Journal of Orthopaedic Surgery & TraumatologyVol. 35(1)
University of Bern (CH), University Hospital of Bern (CH)
University of Bern
Openalex Percentile: Top 27%
Pelvic and Acetabular Injuries
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of the true lateral fluoroscopic projection for the relation of the S1 recess/foramen to safe corridors in transiliac-transsacral screw placement in human cadaveric pelves — Jan Gewiess, Christoph E. Albers, et al. · European Journal of Orthopaedic Surgery & Traumatology (2024) | TGRS Research Map | TGRS