Assessment of Platelet Response to Aspirin Therapy and Hemocompatibility-Related Adverse Events in HeartMate 3 Left Ventricular Assist Device Recipients

<b>Background</b>: Patients with a HeartMate 3 (HM3) left ventricular assist device (LVAD) typically receive anticoagulation and antiplatelet therapy. The HM3 has shown a marked reduction in hemocompatibility-related adverse events (HRAEs) like stroke, bleeding, and pump thrombosis. This study evaluated whether aspirin (ASA) response influences HRAE incidence and if ASA sensitivity changes over time in HM3 recipients. <b>Methods</b>: This single-center, cross-sectional study included 32 HM3 patients (age: 59.0 ± 10.0 years, 15.6% female). ASA sensitivity was assessed twice using the VerifyNow assay, with ASA resistance defined by ASA reactivity units (ARU) > 550. The primary endpoint was HRAE incidence in ASA responders vs. non-responders over two consecutive follow-ups; the secondary endpoint was temporal changes in ASA resistance. <b>Results</b>: At the first follow-up, 13 (40.6%) patients were ASA-resistant, and 8 (28.6%) were resistant at the second follow-up, without significant change (<i>p</i> = 0.22). ASA non-responders and responders had similar ASA doses and baseline characteristics. No significant difference in HRAE incidence was found between ASA non-responders and responders (0.0% vs. 15.8%, <i>p</i> = 0.14), and no additional HRAEs occurred during follow-up. <b>Conclusions</b>: ASA resistance varied considerably among HM3 patients without significant temporal changes, and the demonstrated excellent hemocompatibility supports recent evidence that ASA may have a limited role in the antithrombotic regimen for HM3 recipients.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-11-28
DOI
https://doi.org/10.3390/jcm13237234
Citations
2
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Platelet Response to Aspirin Therapy and Hemocompatibility-Related Adverse Events in HeartMate 3 Left Ventricular Assist Device Recipients

Anne‐Kristin Schaefer, Christiane Marko, Theodor Abart, R. Moayedifar et al.
2 citations
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
0.37
article

Assessment of Platelet Response to Aspirin Therapy and Hemocompatibility-Related Adverse Events in HeartMate 3 Left Ventricular Assist Device Recipients

Anne‐Kristin Schaefer, Christiane Marko, Theodor Abart, R. Moayedifar, Caroline Schwarz, Daniel Zimpfer, Julia Riebandt, Barbara Meßner, Thomas Schlöglhofer, Hebe Al Asadi
article en
2 citations

Abstract

<b>Background</b>: Patients with a HeartMate 3 (HM3) left ventricular assist device (LVAD) typically receive anticoagulation and antiplatelet therapy. The HM3 has shown a marked reduction in hemocompatibility-related adverse events (HRAEs) like stroke, bleeding, and pump thrombosis. This study evaluated whether aspirin (ASA) response influences HRAE incidence and if ASA sensitivity changes over time in HM3 recipients. <b>Methods</b>: This single-center, cross-sectional study included 32 HM3 patients (age: 59.0 ± 10.0 years, 15.6% female). ASA sensitivity was assessed twice using the VerifyNow assay, with ASA resistance defined by ASA reactivity units (ARU) > 550. The primary endpoint was HRAE incidence in ASA responders vs. non-responders over two consecutive follow-ups; the secondary endpoint was temporal changes in ASA resistance. <b>Results</b>: At the first follow-up, 13 (40.6%) patients were ASA-resistant, and 8 (28.6%) were resistant at the second follow-up, without significant change (<i>p</i> = 0.22). ASA non-responders and responders had similar ASA doses and baseline characteristics. No significant difference in HRAE incidence was found between ASA non-responders and responders (0.0% vs. 15.8%, <i>p</i> = 0.14), and no additional HRAEs occurred during follow-up. <b>Conclusions</b>: ASA resistance varied considerably among HM3 patients without significant temporal changes, and the demonstrated excellent hemocompatibility supports recent evidence that ASA may have a limited role in the antithrombotic regimen for HM3 recipients.

Journal of Clinical MedicineVol. 13(23)
Ludwig Boltzmann Institute for Cancer Research (AT), Ludwig Boltzmann Institute for Digital Health and Prevention (AT), Medical University of Vienna (AT)
Good health and well-being
Openalex Percentile: Top 42%
Mechanical Circulatory Support Devices
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.