Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion's adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N<sub>2</sub> complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm<sup>-1</sup> spectral range) can be recorded in as short as 2 s for high throughput measurements. This work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-11-28
DOI
https://doi.org/10.1021/acs.analchem.4c04780
Citations
8
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.93
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

Christopher Harrilal, Sandilya Garimella, Yehia Ibrahim, Randolph V. Norheim
8 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
1.93
article

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

Christopher Harrilal, Sandilya Garimella, Yehia Ibrahim, Randolph V. Norheim
article en
8 citations

Abstract

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion's adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N<sub>2</sub> complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm<sup>-1</sup> spectral range) can be recorded in as short as 2 s for high throughput measurements. This work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

Analytical ChemistryVol. 97(4)
Pacific Northwest National Laboratory (US)
Affordable and clean energy
Openalex Percentile: Top 14%
Mass Spectrometry Techniques and Applications
1.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.