Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters

Reducing total nitrogen (TN) presents a significant challenge for numerous wastewater treatment facilities. In order to address this issue, the current study employed a biological aerated filter for the treatment of wastewater containing low nitrogen concentrations. Both lab-scale and pilot-scale biofilters were constructed to investigate the denitrification performance and maximum denitrification load. The findings indicated that the anaerobic denitrification process of established biofilm adhered to pseudo-first-order kinetics. The results of batch testing and continuous-flow experiments confirmed that the minimum hydraulic retention time (HRT) required for mature biofilm was determined to be 0.5 h. The optimal operating parameters were found to be as follows: influent NO<sub>3</sub> <sup>-</sup>-N concentration of 25 mg/L, HRT of 0.5 h, resulting in effluent TN levels below 1 mg/L. Under these conditions, the denitrifying load for the lab-scale I-BAF system was calculated to be 1.26 kg (TN)/(m<sup>3</sup>·d). Furthermore, it was observed that the maximum denitrifying load could reach 2.2 kg (TN)/(m<sup>3</sup>·d) when the influent NO<sub>3</sub> <sup>-</sup>-N concentration was increased to 50 mg/L while maintaining an HRT of 0.5 h. For the mature biofilter, the appropriate HRT ranged from 2 h to 0.5 h. Microbial diversity analysis revealed that the genus <i>Enterobacter</i> was dominant in all denitrification systems, followed by <i>Comamonas</i> and <i>Rhodococcus</i>. The operational parameters described in the paper could be recommended for a full-scale wastewater treatment facility.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2024-11-28
DOI
https://doi.org/10.3389/fbioe.2024.1463544
Citations
3
Primary Topic
Wastewater Treatment and Nitrogen Removal
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters

Juan Li, Ziru Niu, Lei Li, Shuting Zhou
3 citations
Frontiers in Bioengineering and Biotechnology
Wastewater Treatment and Nitrogen Removal
0.40
article

Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters

Juan Li, Ziru Niu, Lei Li, Shuting Zhou
article en
3 citations

Abstract

Reducing total nitrogen (TN) presents a significant challenge for numerous wastewater treatment facilities. In order to address this issue, the current study employed a biological aerated filter for the treatment of wastewater containing low nitrogen concentrations. Both lab-scale and pilot-scale biofilters were constructed to investigate the denitrification performance and maximum denitrification load. The findings indicated that the anaerobic denitrification process of established biofilm adhered to pseudo-first-order kinetics. The results of batch testing and continuous-flow experiments confirmed that the minimum hydraulic retention time (HRT) required for mature biofilm was determined to be 0.5 h. The optimal operating parameters were found to be as follows: influent NO<sub>3</sub> <sup>-</sup>-N concentration of 25 mg/L, HRT of 0.5 h, resulting in effluent TN levels below 1 mg/L. Under these conditions, the denitrifying load for the lab-scale I-BAF system was calculated to be 1.26 kg (TN)/(m<sup>3</sup>·d). Furthermore, it was observed that the maximum denitrifying load could reach 2.2 kg (TN)/(m<sup>3</sup>·d) when the influent NO<sub>3</sub> <sup>-</sup>-N concentration was increased to 50 mg/L while maintaining an HRT of 0.5 h. For the mature biofilter, the appropriate HRT ranged from 2 h to 0.5 h. Microbial diversity analysis revealed that the genus <i>Enterobacter</i> was dominant in all denitrification systems, followed by <i>Comamonas</i> and <i>Rhodococcus</i>. The operational parameters described in the paper could be recommended for a full-scale wastewater treatment facility.

Frontiers in Bioengineering and BiotechnologyVol. 12
Ministry of Natural Resources (CN), Suzhou University of Science and Technology (CN), Hua Medicine (China) (CN), Land Consolidation and Rehabilitation Center (CN), Shaanxi Provincial Land Engineering Construction Group
Clean water and sanitation
Openalex Percentile: Top 46%
Wastewater Treatment and Nitrogen Removal
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.