Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response

Integrated energy systems (IESs) have been implemented with the objective of enhancing the efficiency of energy utilization and facilitating the sustainable transition of society and energy systems. To further explore the multi-energy coupling capacity and carbon reduction potential of the IESs, this study presents the design of an integrated cold-electricity-heat energy system (ICEHS) with advanced adiabatic compressed air energy storage (AA-CAES). AA-CAES has the capacity to not only store and release electric energy, but also to provide cold and heat energy, which makes it an ideal choice for this application. The main work of this study is fourfold: (1) the energy hub concept is employed to describe the energy transformations within AA-CAES, thereby reducing the modeling complexity; (2) integrated demand response (IDR) for cooling, heating, and electric loads, including shiftable loads, adjustable loads, interruptible loads, and replaceable loads, is considered; (3) Latin hypercubic sampling in conjunction with K-means clustering is employed to address the issue of source-load uncertainty; and (4) an ICEHS operation optimization model is developed with the objective of minimizing the daily operating cost, where the possible cost terms include energy purchase cost, operation and maintenance cost, demand response cost, and carbon emission cost. A typical community integrated energy system is employed as an illustrative example, and four different scenarios are established to validate the effectiveness of the proposed model. The results indicate that AA-CAES and IDR can effectively reduce the daily operating cost and carbon emissions of an ICEHS. In comparison to the scenario that did not incorporate AA-CAES and IDR, the daily operating cost and carbon emissions are reduced by 4.8% and 10.3%, respectively.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-11-28
DOI
https://doi.org/10.3390/en17236000
Citations
4
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.83

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response

Lilin Peng, Danhao Chen, Tiannan Ma, Xin Zou et al.
4 citations
Energies
Integrated Energy Systems Optimization
0.83
article

Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response

Lilin Peng, Danhao Chen, Tiannan Ma, Xin Zou, Gang Wu
article en
4 citations

Abstract

Integrated energy systems (IESs) have been implemented with the objective of enhancing the efficiency of energy utilization and facilitating the sustainable transition of society and energy systems. To further explore the multi-energy coupling capacity and carbon reduction potential of the IESs, this study presents the design of an integrated cold-electricity-heat energy system (ICEHS) with advanced adiabatic compressed air energy storage (AA-CAES). AA-CAES has the capacity to not only store and release electric energy, but also to provide cold and heat energy, which makes it an ideal choice for this application. The main work of this study is fourfold: (1) the energy hub concept is employed to describe the energy transformations within AA-CAES, thereby reducing the modeling complexity; (2) integrated demand response (IDR) for cooling, heating, and electric loads, including shiftable loads, adjustable loads, interruptible loads, and replaceable loads, is considered; (3) Latin hypercubic sampling in conjunction with K-means clustering is employed to address the issue of source-load uncertainty; and (4) an ICEHS operation optimization model is developed with the objective of minimizing the daily operating cost, where the possible cost terms include energy purchase cost, operation and maintenance cost, demand response cost, and carbon emission cost. A typical community integrated energy system is employed as an illustrative example, and four different scenarios are established to validate the effectiveness of the proposed model. The results indicate that AA-CAES and IDR can effectively reduce the daily operating cost and carbon emissions of an ICEHS. In comparison to the scenario that did not incorporate AA-CAES and IDR, the daily operating cost and carbon emissions are reduced by 4.8% and 10.3%, respectively.

EnergiesVol. 17(23)
North China Electric Power University (CN)
Science and Technology Project of State Grid
Openalex Percentile: Top 26%
Integrated Energy Systems Optimization
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimized Operation of Integrated Cooling-Electricity-Heat Energy Systems with AA-CAES and Integrated Demand Response — Lilin Peng, Danhao Chen, et al. · Energies (2024) | TGRS Research Map | TGRS