Degradation and Fatigue Behavior of <scp>3D</scp>‐Printed Bioresorbable Tracheal Splints

Severe infantile tracheobronchomalacia (TBM) is often treated with invasive surgery and fixed-size implants to support the trachea during respiration. A novel 3D-printed extra-luminal splint has been developed as a flexible and bioresorbable alternative. Therefore, the goal of the present study was to use an in vitro breathing simulator model to comprehensively evaluate the structural stiffness and failure modes of two sizes of a novel bioresorbable 3D-printed splint design under a range of physiological degradation conditions. Two thicknesses, 2 mm and 3 mm, of a novel 3D-printed bioresorbable splint were evaluated under two different degradation conditions, phosphate-buffered saline (PBS) and sodium hydroxide (NaOH). The splints were subjected to simulated breathing loading, involving a cyclic opening and closing of the splint by 2 mm, for a targeted duration of 7.5 to 30 million cycles. A separate new set of splints were statically soaked in their respective degradation condition for a comparative analysis of the effects of cyclic loading by the degradation medium. After successfully simulated breathing or static soaking, non-destructive tensile and compressive strengths were evaluated, and overall stiffness was calculated from destructive tensile testing. The present study indicates that the splints were more significantly degraded under simulated breathing conditions than under soaking. Cyclic simulated breathing specimens failed far earlier than the intended duration of loading. Over time, both 2 mm and 3 mm splints became increasingly more flexible when subjected to the static degradation conditions. Interestingly, there was little difference in the compressive and tensile strengths of the 2 mm and 3 mm thickness splints. The bioresorbable nature of PCL offers a valuable advantage as it eliminates the need for splint removal surgery and increases device flexibility over time with degradation. This increased flexibility is crucial because it allows for uninhibited growth and development of the infant's trachea over the intended use period of 2 years. The results of this study confirm that the splints were able to withstand tensile forces to prevent tracheal collapse. This study further supports the successful use of 3D-printed splints in the treatment of infantile TBM.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2024-11-28
DOI
https://doi.org/10.1002/jbm.b.35501
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Degradation and Fatigue Behavior of 3D‐Printed Bioresorbable Tracheal Splints

Scott J. Hollister, Sophia N. Sangiorgio, Jenna M. Wahbeh, Edward Ebramzadeh et al.
Journal of Biomedical Materials Research Part B Applied Biomaterials
Tracheal and airway disorders
article

Degradation and Fatigue Behavior of 3D‐Printed Bioresorbable Tracheal Splints

Scott J. Hollister, Sophia N. Sangiorgio, Jenna M. Wahbeh, Edward Ebramzadeh, John Lama, Sang‐Hyun Park
article en

Abstract

Severe infantile tracheobronchomalacia (TBM) is often treated with invasive surgery and fixed-size implants to support the trachea during respiration. A novel 3D-printed extra-luminal splint has been developed as a flexible and bioresorbable alternative. Therefore, the goal of the present study was to use an in vitro breathing simulator model to comprehensively evaluate the structural stiffness and failure modes of two sizes of a novel bioresorbable 3D-printed splint design under a range of physiological degradation conditions. Two thicknesses, 2 mm and 3 mm, of a novel 3D-printed bioresorbable splint were evaluated under two different degradation conditions, phosphate-buffered saline (PBS) and sodium hydroxide (NaOH). The splints were subjected to simulated breathing loading, involving a cyclic opening and closing of the splint by 2 mm, for a targeted duration of 7.5 to 30 million cycles. A separate new set of splints were statically soaked in their respective degradation condition for a comparative analysis of the effects of cyclic loading by the degradation medium. After successfully simulated breathing or static soaking, non-destructive tensile and compressive strengths were evaluated, and overall stiffness was calculated from destructive tensile testing. The present study indicates that the splints were more significantly degraded under simulated breathing conditions than under soaking. Cyclic simulated breathing specimens failed far earlier than the intended duration of loading. Over time, both 2 mm and 3 mm splints became increasingly more flexible when subjected to the static degradation conditions. Interestingly, there was little difference in the compressive and tensile strengths of the 2 mm and 3 mm thickness splints. The bioresorbable nature of PCL offers a valuable advantage as it eliminates the need for splint removal surgery and increases device flexibility over time with degradation. This increased flexibility is crucial because it allows for uninhibited growth and development of the infant's trachea over the intended use period of 2 years. The results of this study confirm that the splints were able to withstand tensile forces to prevent tracheal collapse. This study further supports the successful use of 3D-printed splints in the treatment of infantile TBM.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 112(12)
Georgia Institute of Technology (US), University of California, Los Angeles (US), Orthopaedic Institute for Children (US)
National Institutes of Health
Life in Land
Openalex Percentile: Top 60%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.