Treatment performance of different units in the anaerobic-anoxic-aerobic process of landfill leachate under antibiotic exposure

The effectiveness of three different treatment units (anaerobic, anoxic, and aerobic) in A/A/O reactors when treating landfill leachate that contained varying concentrations of tetracycline (TC) was evaluated. The effluent quality, sludge performance, and removal rates of COD, TN, TP, and NH<sub>3</sub>-N of the reactors were investigated. The results showed that in the three treatment units (anaerobic, anoxic, and aerobic), when the TC dosage was 10 mg/L, the removal rates of NH<sub>3</sub>-N continued to decrease to 6.9%, 16.3%, and 32.8%, and the removal rates of COD, TN, and TP in the three treatment units reached their maximum values, which were 37.5%, 57.4%, and 69.6%; 21.1%, 37.1%, and 41.0%; 13.0%, 16.2%, and 27.4%, respectively. During the reactor's operation, the heavy metal content in the treatment units initially increased followed by a decrease, especially for Mn and Zn. This was due to the production of more EPS by microorganisms, resulting in more active sites for heavy metal adsorption. In addition, with the increase of TC concentration, TC removal rate was always positively correlated with PN, COD, TN and heavy metals removal rates, and negatively correlated with NH<sub>3</sub>-N, TP, pH, and PS. Further analysis revealed that TC was toxic to microorganisms, leading to a decrease in biodiversity and microbial community diversity among the three treatment units in the reactor. This article analyzed the treatment effects of different treatment units in leachate under antibiotic exposure conditions, to explore better external conditions for sewage biological treatment facilities.

Authors

Institutions

Publication Details

Journal
Environmental Technology
Published
2024-11-28
DOI
https://doi.org/10.1080/09593330.2024.2433728
Citations
1
Primary Topic
Pharmaceutical and Antibiotic Environmental Impacts
Type
article
Field-Weighted Citation Impact
0.13

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Treatment performance of different units in the anaerobic-anoxic-aerobic process of landfill leachate under antibiotic exposure

Libo Qiu, Xiangdong Xue, Siyi Li, Ming Zhou et al.
1 citations
Environmental Technology
Pharmaceutical and Antibiotic Environmental Impacts
0.13
article

Treatment performance of different units in the anaerobic-anoxic-aerobic process of landfill leachate under antibiotic exposure

Libo Qiu, Xiangdong Xue, Siyi Li, Ming Zhou, Chengran Fang, Yanli Ding, Hong Li, Yiting Lian
article en
1 citations

Abstract

The effectiveness of three different treatment units (anaerobic, anoxic, and aerobic) in A/A/O reactors when treating landfill leachate that contained varying concentrations of tetracycline (TC) was evaluated. The effluent quality, sludge performance, and removal rates of COD, TN, TP, and NH<sub>3</sub>-N of the reactors were investigated. The results showed that in the three treatment units (anaerobic, anoxic, and aerobic), when the TC dosage was 10 mg/L, the removal rates of NH<sub>3</sub>-N continued to decrease to 6.9%, 16.3%, and 32.8%, and the removal rates of COD, TN, and TP in the three treatment units reached their maximum values, which were 37.5%, 57.4%, and 69.6%; 21.1%, 37.1%, and 41.0%; 13.0%, 16.2%, and 27.4%, respectively. During the reactor's operation, the heavy metal content in the treatment units initially increased followed by a decrease, especially for Mn and Zn. This was due to the production of more EPS by microorganisms, resulting in more active sites for heavy metal adsorption. In addition, with the increase of TC concentration, TC removal rate was always positively correlated with PN, COD, TN and heavy metals removal rates, and negatively correlated with NH<sub>3</sub>-N, TP, pH, and PS. Further analysis revealed that TC was toxic to microorganisms, leading to a decrease in biodiversity and microbial community diversity among the three treatment units in the reactor. This article analyzed the treatment effects of different treatment units in leachate under antibiotic exposure conditions, to explore better external conditions for sewage biological treatment facilities.

Environmental TechnologyVol. 46(13)
Zhejiang University of Science and Technology (CN), State Development & Investment Corporation (China) (CN), Zhejiang University of Technology (CN)
National Natural Science Foundation of China
Clean water and sanitation
Openalex Percentile: Top 59%
Pharmaceutical and Antibiotic Environmental Impacts
0.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.