Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples

Plasma viscosity measurement is crucial in clinical diagnostics, providing insights into blood rheology and health status. Traditional methods, such as capillary and rotational viscometers, require large sample volumes and complex calibration. This study presents a novel disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples. The sensor independently determines the diffusion coefficient (D) of the electroactive test molecule ferrocyanide, eliminating the need for calibration curves. This enables the subsequent calculation of the solution's viscosity via the Stokes-Einstein relation. The sensor's performance was validated against a standard quartz-crystal microbalance method, demonstrating high accuracy and reliability. It maintained consistent measurements despite the presence of common electroactive plasma interferents such as ascorbic acid (≤160 μM), dopamine (<9.0 nM), uric acid (<1.0 mM), and urea (<15.6 mM). Although these interferents impacted D at concentrations exceeding twice the maximum levels typically present in plasma, the sensor exhibited robust performance under normal physiological conditions and standard interferent concentrations. The sensor offers rapid response times of less than 20 s, requires only 7 μL of sample, and is cost-effective, making it suitable for point-of-care applications. Bland-Altman plot analysis confirmed its precision, showing a mean difference of 0.00877 and narrow limits of agreement compared to the standard method used.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2024-11-28
DOI
https://doi.org/10.1016/j.talanta.2024.127290
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples

Ashwin K. V. Mruthunjaya, Angel A. J. Torriero, Megan J Fitz
1 citations
Talanta
Analytical Chemistry and Sensors
0.29
article

Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples

Ashwin K. V. Mruthunjaya, Angel A. J. Torriero, Megan J Fitz
article en
1 citations

Abstract

Plasma viscosity measurement is crucial in clinical diagnostics, providing insights into blood rheology and health status. Traditional methods, such as capillary and rotational viscometers, require large sample volumes and complex calibration. This study presents a novel disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples. The sensor independently determines the diffusion coefficient (D) of the electroactive test molecule ferrocyanide, eliminating the need for calibration curves. This enables the subsequent calculation of the solution's viscosity via the Stokes-Einstein relation. The sensor's performance was validated against a standard quartz-crystal microbalance method, demonstrating high accuracy and reliability. It maintained consistent measurements despite the presence of common electroactive plasma interferents such as ascorbic acid (≤160 μM), dopamine (<9.0 nM), uric acid (<1.0 mM), and urea (<15.6 mM). Although these interferents impacted D at concentrations exceeding twice the maximum levels typically present in plasma, the sensor exhibited robust performance under normal physiological conditions and standard interferent concentrations. The sensor offers rapid response times of less than 20 s, requires only 7 μL of sample, and is cost-effective, making it suitable for point-of-care applications. Bland-Altman plot analysis confirmed its precision, showing a mean difference of 0.00877 and narrow limits of agreement compared to the standard method used.

TalantaVol. 285
Deakin University (AU)
Affordable and clean energy
Openalex Percentile: Top 45%
Analytical Chemistry and Sensors
0.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibration-free disposable electrochemical sensor with co-facing electrodes for viscosity monitoring of plasma samples — Ashwin K. V. Mruthunjaya, Angel A. J. Torriero, et al. · Talanta (2024) | TGRS Research Map | TGRS