Analysis of fringe field effects on measurement errors for Q-scanning-based emittance diagnosis system

As a widely recognized emittance measurement technique, the Q-scanning method typically plays a crucial role in the commissioning process of accelerator-based beam injectors. The Q-magnet, being a pivotal component, significantly influences the measurement capability, thus warranting detailed examination in this study. By reassessing the measurement outcomes of the Q-magnet, the impact of fringe fields on emittance measurement precision is thoroughly scrutinized within this framework. Subsequently, corrections to the transfer matrices of the Q-scanning system under different excitation currents are implemented by revisiting fundamental beam optic principles. Moreover, virtual measurements via both theoretical calculations and beam dynamics simulations are conducted to validate these corrections, utilizing the setup of an existing beam injector established at Huazhong University of Science and Technology. Both the theoretical and experimental results indicate that the measurement accuracy of the Q-scanning technique can be improved by correcting the fringe field effects.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2024-11-28
DOI
https://doi.org/10.1016/j.net.2024.103344
Citations
2
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of fringe field effects on measurement errors for Q-scanning-based emittance diagnosis system

Y. F. Zeng, H. Hu, Tongning Hu, Yuntian Wang
2 citations
Nuclear Engineering and Technology
Advanced Sensor Technologies Research
0.37
article

Analysis of fringe field effects on measurement errors for Q-scanning-based emittance diagnosis system

Y. F. Zeng, H. Hu, Tongning Hu, Yuntian Wang
article en
2 citations

Abstract

As a widely recognized emittance measurement technique, the Q-scanning method typically plays a crucial role in the commissioning process of accelerator-based beam injectors. The Q-magnet, being a pivotal component, significantly influences the measurement capability, thus warranting detailed examination in this study. By reassessing the measurement outcomes of the Q-magnet, the impact of fringe fields on emittance measurement precision is thoroughly scrutinized within this framework. Subsequently, corrections to the transfer matrices of the Q-scanning system under different excitation currents are implemented by revisiting fundamental beam optic principles. Moreover, virtual measurements via both theoretical calculations and beam dynamics simulations are conducted to validate these corrections, utilizing the setup of an existing beam injector established at Huazhong University of Science and Technology. Both the theoretical and experimental results indicate that the measurement accuracy of the Q-scanning technique can be improved by correcting the fringe field effects.

Nuclear Engineering and TechnologyVol. 57(5)
Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China
Reduced inequalities
Openalex Percentile: Top 42%
Advanced Sensor Technologies Research
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.