Design of a Wearable Dynamic Respiratory Monitoring System Based on a Distributed Inertial Measurement Unit

Inertial measurement units (IMUs)-based respiration signal detection provides a low-cost, noninvasive approach to measure the volumetric changes of the thorax and abdomen as a consequence of respiration. In view of the challenges of body motion interference to respiration detection in dynamic scenarios, this article proposes a distributed IMU respiratory detection method that allocates two IMUs onto the lower back and chest, respectively, to concurrently record the trunk motions and the respiration activities. Different positions of the IMUs are evaluated to optimize the effective capturing of the respiration signal and the suppression of motion interference. The principal component analysis (PCA) is applied to dynamically select the components under different motion modes to extract the respiratory signal, combining with a joint discrete Fourier transform (DFT) and empirical mode decomposition (EMD) denoising processing. Finally, the Savitzky-Golay filter (SGF) and the Butterworth bandpass filter (BPF) are used to optimize the respiratory signal quality. The proposed method is evaluated in standing, sitting, walking, and squatting motions under different subjects using the Xsens DOT IMU sensors for measurements, and the TI ADS1298R evaluation kit as the reference respiration signal recording by means of impedance pneumography. The experimental results show that the root mean square error (RMSE) between the measurements and the references under different activity states is less than 0.8, and their correlation coefficient is larger than 0.7, showing excellent measurement accuracy and robustness. The results show the potential of distributed IMU respiration measuring in dynamic scenarios and are expected to overcome complex motion interferences in various motion modes.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-11-28
DOI
https://doi.org/10.1109/jsen.2024.3504826
Citations
3
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.62

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a Wearable Dynamic Respiratory Monitoring System Based on a Distributed Inertial Measurement Unit

Tao Wan, Yang Tong, Mengran Duan, Lingfeng Liu et al.
3 citations
IEEE Sensors Journal
Air Quality Monitoring and Forecasting
0.62
article

Design of a Wearable Dynamic Respiratory Monitoring System Based on a Distributed Inertial Measurement Unit

Tao Wan, Yang Tong, Mengran Duan, Lingfeng Liu, Hanrui Jiang, Hao Cheng, Siyu Li
article en
3 citations

Abstract

Inertial measurement units (IMUs)-based respiration signal detection provides a low-cost, noninvasive approach to measure the volumetric changes of the thorax and abdomen as a consequence of respiration. In view of the challenges of body motion interference to respiration detection in dynamic scenarios, this article proposes a distributed IMU respiratory detection method that allocates two IMUs onto the lower back and chest, respectively, to concurrently record the trunk motions and the respiration activities. Different positions of the IMUs are evaluated to optimize the effective capturing of the respiration signal and the suppression of motion interference. The principal component analysis (PCA) is applied to dynamically select the components under different motion modes to extract the respiratory signal, combining with a joint discrete Fourier transform (DFT) and empirical mode decomposition (EMD) denoising processing. Finally, the Savitzky-Golay filter (SGF) and the Butterworth bandpass filter (BPF) are used to optimize the respiratory signal quality. The proposed method is evaluated in standing, sitting, walking, and squatting motions under different subjects using the Xsens DOT IMU sensors for measurements, and the TI ADS1298R evaluation kit as the reference respiration signal recording by means of impedance pneumography. The experimental results show that the root mean square error (RMSE) between the measurements and the references under different activity states is less than 0.8, and their correlation coefficient is larger than 0.7, showing excellent measurement accuracy and robustness. The results show the potential of distributed IMU respiration measuring in dynamic scenarios and are expected to overcome complex motion interferences in various motion modes.

IEEE Sensors JournalVol. 25(2)
East China Jiaotong University (CN)
Major Discipline Academic and Technical Leaders Training Program of Jiangxi Province, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 34%
Air Quality Monitoring and Forecasting
0.62
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.