Compact and full-range carbon dioxide sensor using photoacoustic and resonance dependent modes

A compact and robust optical excitation photoacoustic sensor with a self-integrated laser module excitation and an optimized differential resonator was developed to achieve high sensitivity and full linear range detection of carbon dioxide (CO<sub>2</sub>) based on dual modes of wavelength modulated photoacoustic spectroscopy (WMPAS) and resonant frequency tracking (RFT). The integrated laser module equipped with three lasers (a quantum cascade laser (QCL), a distributed feedback laser (DFB) and a He-Ne laser) working in a time-division multiplexing mode was used as an integrated set of spectroscopic sources for detection of the designated concentration levels of CO<sub>2</sub>. With the absorption photoacoustic mode, the WMPAS detection with the QCL and DFB sources was capable of CO<sub>2</sub> detection at concentrations below 20 %, yielding a noise equivalent concentration (NEC) as low as 240 ppt and a normalized noise equivalent absorption coefficient (NNEA) of 4.755 × 10<sup>-10</sup> W cm<sup>-1</sup>/√Hz, and dynamic range as great as 11 orders of magnitude. Higher concentration detection ranges (20 %-100 %) of CO<sub>2</sub> were investigated using the RFT mode with an amplitude-stabilized He-Ne laser and a mechanical chopper. With the dual modes of WMPAS and RFT, the optical excitation sensor achieved full-range CO<sub>2</sub> detection, with an R² ≥ 0.9993 and a response time of 5 seconds. The compact and full-range CO<sub>2</sub> sensor combines the advantages of WMPAS and RFT and offers a solution for high sensitivity, linearity and full-range CO<sub>2</sub> detection.

Authors

Institutions

Publication Details

Journal
Photoacoustics
Published
2024-11-29
DOI
https://doi.org/10.1016/j.pacs.2024.100669
Citations
6
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
1.25

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compact and full-range carbon dioxide sensor using photoacoustic and resonance dependent modes

Huiting Huan, Andreas Mandelis, Xueshi Zhang, Jiyong Zhang et al.
6 citations
Photoacoustics
Gas Sensing Nanomaterials and Sensors
1.25
article

Compact and full-range carbon dioxide sensor using photoacoustic and resonance dependent modes

Huiting Huan, Andreas Mandelis, Xueshi Zhang, Jiyong Zhang, Roberto Li Voti, Yize Liang, Liang Zhao, Xiaopeng Shao, Lixian Liu, Yifan Li, Le Zhang, Jialiang Sun
article en
6 citations

Abstract

A compact and robust optical excitation photoacoustic sensor with a self-integrated laser module excitation and an optimized differential resonator was developed to achieve high sensitivity and full linear range detection of carbon dioxide (CO<sub>2</sub>) based on dual modes of wavelength modulated photoacoustic spectroscopy (WMPAS) and resonant frequency tracking (RFT). The integrated laser module equipped with three lasers (a quantum cascade laser (QCL), a distributed feedback laser (DFB) and a He-Ne laser) working in a time-division multiplexing mode was used as an integrated set of spectroscopic sources for detection of the designated concentration levels of CO<sub>2</sub>. With the absorption photoacoustic mode, the WMPAS detection with the QCL and DFB sources was capable of CO<sub>2</sub> detection at concentrations below 20 %, yielding a noise equivalent concentration (NEC) as low as 240 ppt and a normalized noise equivalent absorption coefficient (NNEA) of 4.755 × 10<sup>-10</sup> W cm<sup>-1</sup>/√Hz, and dynamic range as great as 11 orders of magnitude. Higher concentration detection ranges (20 %-100 %) of CO<sub>2</sub> were investigated using the RFT mode with an amplitude-stabilized He-Ne laser and a mechanical chopper. With the dual modes of WMPAS and RFT, the optical excitation sensor achieved full-range CO<sub>2</sub> detection, with an R² ≥ 0.9993 and a response time of 5 seconds. The compact and full-range CO<sub>2</sub> sensor combines the advantages of WMPAS and RFT and offers a solution for high sensitivity, linearity and full-range CO<sub>2</sub> detection.

PhotoacousticsVol. 41
Canadian Institute for Advanced Research (CA), Xidian University (CN), Northwest Institute of Nuclear Technology (CN), Hangzhou Dianzi University (CN), Sapienza University of Rome (IT)
National Natural Science Foundation of China, Xidian University, Natural Science Foundation of Shaanxi Province, Yakult Bio-Science Foundation, Natural Sciences and Engineering Research Council of Canada, Fundamental Research Funds for the Central Universities, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 19%
Gas Sensing Nanomaterials and Sensors
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.