Margin and robustness settings for a library-of-plans IMPT strategy for locally advanced cervical cancer
<i>Objective.</i>This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).<i>Approach.</i>We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2-7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume.<i>Main results.</i>The percentage of treatments that reach the dose criterion<i>V</i><sub>42.75Gy</sub>> 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction.<i>Significance.</i>Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.
Authors
- Jérémy Godart (ORCID: https://orcid.org/0000-0001-5070-8128)
- Anouk Corbeau (ORCID: https://orcid.org/0000-0003-3919-5135)
- Remi A. Nout (ORCID: https://orcid.org/0000-0001-8011-2982)
- Sander C. Kuipers (ORCID: https://orcid.org/0000-0002-8844-6749)
- Heloisa H. Deuzeman (ORCID: https://orcid.org/0000-0003-3282-8497)
- András Zolnay (ORCID: https://orcid.org/0000-0001-8476-9092)
- Stephanie M. de Boer (ORCID: https://orcid.org/0000-0002-8454-1597)
- Mischa S. Hoogeman (ORCID: https://orcid.org/0000-0002-4264-9903)
- Eva M Negenman
Institutions
- Leiden University Medical Center (NL)
- Erasmus MC Cancer Institute (NL)
Publication Details
- Journal
- Physics in Medicine and Biology
- Published
- 2024-11-28
- DOI
- https://doi.org/10.1088/1361-6560/ad9882
- Citations
- 1
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.61
Funders
- Varian Medical Systems