Margin and robustness settings for a library-of-plans IMPT strategy for locally advanced cervical cancer

<i>Objective.</i>This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).<i>Approach.</i>We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2-7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume.<i>Main results.</i>The percentage of treatments that reach the dose criterion<i>V</i><sub>42.75Gy</sub>> 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction.<i>Significance.</i>Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-11-28
DOI
https://doi.org/10.1088/1361-6560/ad9882
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Margin and robustness settings for a library-of-plans IMPT strategy for locally advanced cervical cancer

Jérémy Godart, Anouk Corbeau, Remi A. Nout, Sander C. Kuipers et al.
1 citations
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
0.61
article

Margin and robustness settings for a library-of-plans IMPT strategy for locally advanced cervical cancer

Jérémy Godart, Anouk Corbeau, Remi A. Nout, Sander C. Kuipers, Heloisa H. Deuzeman, András Zolnay, Stephanie M. de Boer, Mischa S. Hoogeman, Eva M Negenman
article en
1 citations

Abstract

<i>Objective.</i>This study aims to determine a margin and robustness setting for treating locally advanced cervical cancer (LACC) with a library-of-plans (LoP) based online-adaptive intensity-modulated proton therapy (IMPT).<i>Approach.</i>We analyzed 13 LACC patients with delineated planning and weekly repeat CT scans (reCTs). For each patient, 120 IMPT treatments of 25 fractions were simulated with a LoPs approach. Six different robustness settings (2-7 mm set-up robustness (SR) plus 3% range robustness (RR)) were used to create those 120 IMPT plans. Each fraction was simulated with a weekly reCT, combined with the sampling of inter- and intrafraction treatment uncertainties. The fraction doses were accumulated to obtain a treatment dose to the target volumes, distinguishing between the low-risk clinical target volume (CTV-T-LR) and the elective CTV (CTV-E). If one of the two targets obtained an adequate coverage for more than 90% of the treatments, different anisotropic margins were sampled on top of the robustness setting to the other target to obtain the Pareto-optimal margin in terms of adequate coverage versus increase in target volume.<i>Main results.</i>The percentage of treatments that reach the dose criterion<i>V</i><sub>42.75Gy</sub>> 95% for the CTV-T-LR was 22.3%, 28.5%, 51.2%, 73.1%, 85.3%, and 90.0% for 2, 3, 4, 5, 6, and 7 mm SR plus 3% RR and for the CTV-E, this percentage was 60.4%, 73.8%, 86.5%, 92.3%, 96.9%, and 98.5%. The Pareto-optimal margin combined with a 5 mm/3% robustness setting for the CTV-T-LR with an adequate coverage for >90% of the treatments was given by {0, 1, 0, 3, 3, 0} mm in the left, right, anterior, posterior, cranial, caudal direction.<i>Significance.</i>Our study evaluated combinations of robustness and anisotropic margin settings for IMPT for LACC. With 5 mm SR and 3% RR for CTV-E and CTV-T-LR plus a margin to the CTV-T-LR of {0, 1, 0, 3, 3, 0} mm in left, right, anterior, posterior, cranial, and caudal ensured an adequate coverage for >90% of the simulated IMPT treatments.

Physics in Medicine and BiologyVol. 69(24)
Leiden University Medical Center (NL), Erasmus MC Cancer Institute (NL)
Varian Medical Systems
Good health and well-being
Openalex Percentile: Top 28%
Advanced Radiotherapy Techniques
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.