Assessing the validity of a wearable shoulder motion tracking system through comparison with dartfish in patients undergoing shoulder joint replacement surgery

Objective assessments of shoulder motion are paramount for effective rehabilitation and evaluation of surgical outcomes. Inertial Measurement Units (IMU) have demonstrated promise in providing unbiased movement data. This study is dedicated to evaluating the concurrent construct validity and accuracy of a wearable IMU-based sensor system, called 'Motion Shirt', for the assessment of humero-thoracic motion arcs in patients awaiting shoulder replacement surgery. This evaluation was conducted by comparing Motion Shirt data with the Dartfish Motion Analyzer software during the Functional Impairment Test-Hand and Neck/Shoulder/Arm (FIT-HaNSA) test. Thirteen patients (age > 50), who were awaiting shoulder replacement surgery, were recruited. The Motion Shirt was employed to measure angular humero-thoracic movements in two planes during the FIT-HaNSA test. Simultaneously, two cameras recorded the participants' movements to provide reference data. Bland-Altman plots were generated to visualize agreement between the Motion Shirt and the reference data obtained from the Dartfish Motion Analyzer software. The data analysis on Bland-Altman plots revealed a substantial level of agreement between the Motion Shirt and Dartfish analysis in measuring humero-thoracic motion. In Task-1, no significant systematic errors were exhibited, with only 3.27% and 2.18% of points exceeding the limits of agreement (LOA) in both elevation and the Plane of Elevation (POE), signifying a high level of concordance. In Task-2, a high level of agreement was also observed in Elevation, with only 3.8% of points exceeding the LOA. However, 5.98% of points exceeded LOA in POE for Task-2. In Task-3, focused on sustained overhead activity, the Motion Shirt showed strong agreement with Dartfish in Elevation (2.44% points exceeded LOA), but in POE, 7.32% points exceeded LOA. The Motion Shirt demonstrated a robust concordance with Dartfish Motion Analyzer system in assessing humerothoracic motion during the FIT-HaNSA test. These results affirm the Motion Shirt's suitability for objective motion analysis in patients awaiting shoulder replacement surgery.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2024-11-28
DOI
https://doi.org/10.1088/2057-1976/ad9838
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the validity of a wearable shoulder motion tracking system through comparison with dartfish in patients undergoing shoulder joint replacement surgery

James A. Johnson, G. Daniel G. Langohr, Joy Christine MacDermid, Sohrob Milanizadeh
Biomedical Physics & Engineering Express
Shoulder Injury and Treatment
article

Assessing the validity of a wearable shoulder motion tracking system through comparison with dartfish in patients undergoing shoulder joint replacement surgery

James A. Johnson, G. Daniel G. Langohr, Joy Christine MacDermid, Sohrob Milanizadeh
article en

Abstract

Objective assessments of shoulder motion are paramount for effective rehabilitation and evaluation of surgical outcomes. Inertial Measurement Units (IMU) have demonstrated promise in providing unbiased movement data. This study is dedicated to evaluating the concurrent construct validity and accuracy of a wearable IMU-based sensor system, called 'Motion Shirt', for the assessment of humero-thoracic motion arcs in patients awaiting shoulder replacement surgery. This evaluation was conducted by comparing Motion Shirt data with the Dartfish Motion Analyzer software during the Functional Impairment Test-Hand and Neck/Shoulder/Arm (FIT-HaNSA) test. Thirteen patients (age > 50), who were awaiting shoulder replacement surgery, were recruited. The Motion Shirt was employed to measure angular humero-thoracic movements in two planes during the FIT-HaNSA test. Simultaneously, two cameras recorded the participants' movements to provide reference data. Bland-Altman plots were generated to visualize agreement between the Motion Shirt and the reference data obtained from the Dartfish Motion Analyzer software. The data analysis on Bland-Altman plots revealed a substantial level of agreement between the Motion Shirt and Dartfish analysis in measuring humero-thoracic motion. In Task-1, no significant systematic errors were exhibited, with only 3.27% and 2.18% of points exceeding the limits of agreement (LOA) in both elevation and the Plane of Elevation (POE), signifying a high level of concordance. In Task-2, a high level of agreement was also observed in Elevation, with only 3.8% of points exceeding the LOA. However, 5.98% of points exceeded LOA in POE for Task-2. In Task-3, focused on sustained overhead activity, the Motion Shirt showed strong agreement with Dartfish in Elevation (2.44% points exceeded LOA), but in POE, 7.32% points exceeded LOA. The Motion Shirt demonstrated a robust concordance with Dartfish Motion Analyzer system in assessing humerothoracic motion during the FIT-HaNSA test. These results affirm the Motion Shirt's suitability for objective motion analysis in patients awaiting shoulder replacement surgery.

Biomedical Physics & Engineering ExpressVol. 11(2)
Western University (CA), London Health Sciences Centre (CA), St Joseph's Health Centre (CA), St Joseph's Health Care (CA)
Canadian Institutes of Health Research
Openalex Percentile: Top 59%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.