Development of an Algorithm for Distinguishing Between Transmitted and Reflected Ultrasonic Signals Using A Hybrid Transmission and Reception Method with Non-Contact Ultrasonic Measurement Technology

Although technologies that allow the detection of abnormalities in high voltage electrical installations without power interruption are being applied, there are limitations in clearly determining facility faults. In particular, molded-type electrical equipment has a structure that completely seals internal components from the outside, making it difficult to detect internal anomalies. Therefore, it is challenging to detect early internal faults using existing power-on diagnostic method. In response, a new diagnostic method has been introduced that utilizes ultrasound to penetrate epoxy insulation and estimate the internal temperature of high-voltage molded-type transformer windings, along with a non-contact ultrasonic measurement technology. This paper, based on previous research, develops an algorithm for distinguishing between transmitted and reflected ultrasonic signals using a hybrid transmission and reception method with non-contact ultrasonic measurement technology. The performance of the algorithm was verified using high-voltage winding samples from a molded transformer specially fabricated for the experiment.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2024-11-28
DOI
https://doi.org/10.5370/kiee.2024.73.11.2113
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an Algorithm for Distinguishing Between Transmitted and Reflected Ultrasonic Signals Using A Hybrid Transmission and Reception Method with Non-Contact Ultrasonic Measurement Technology

Ga-Ram Han, Junho Bang, Jeong-Chay Jeon, Hae-Gweon Kang
The Transactions of The Korean Institute of Electrical Engineers
Flow Measurement and Analysis
article

Development of an Algorithm for Distinguishing Between Transmitted and Reflected Ultrasonic Signals Using A Hybrid Transmission and Reception Method with Non-Contact Ultrasonic Measurement Technology

Ga-Ram Han, Junho Bang, Jeong-Chay Jeon, Hae-Gweon Kang
article en

Abstract

Although technologies that allow the detection of abnormalities in high voltage electrical installations without power interruption are being applied, there are limitations in clearly determining facility faults. In particular, molded-type electrical equipment has a structure that completely seals internal components from the outside, making it difficult to detect internal anomalies. Therefore, it is challenging to detect early internal faults using existing power-on diagnostic method. In response, a new diagnostic method has been introduced that utilizes ultrasound to penetrate epoxy insulation and estimate the internal temperature of high-voltage molded-type transformer windings, along with a non-contact ultrasonic measurement technology. This paper, based on previous research, develops an algorithm for distinguishing between transmitted and reflected ultrasonic signals using a hybrid transmission and reception method with non-contact ultrasonic measurement technology. The performance of the algorithm was verified using high-voltage winding samples from a molded transformer specially fabricated for the experiment.

The Transactions of The Korean Institute of Electrical EngineersVol. 73(11)
Openalex Percentile: Top 76%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.