Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine

This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.

Authors

Institutions

Publication Details

Journal
Analytica—A Journal of Analytical Chemistry and Chemical Analysis
Published
2024-11-28
DOI
https://doi.org/10.3390/analytica5040039
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine

Aybüke A. İsbir-Turan, Gül Keklik Şah
1 citations
Analytica—A Journal of Analytical Chemistry and Chemical Analysis
Advanced biosensing and bioanalysis techniques
0.23
article

Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine

Aybüke A. İsbir-Turan, Gül Keklik Şah
article en
1 citations

Abstract

This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.

Analytica—A Journal of Analytical Chemistry and Chemical AnalysisVol. 5(4)
Police Academy (TR), Institute of Forensic Science (CN)
Good health and well-being
Openalex Percentile: Top 41%
Advanced biosensing and bioanalysis techniques
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.