Assessing Total Knee Arthroplasty Implant Balance with a Passive Knee Drop Test

This study investigated the ability of a modified PKD test to quantify the relative change in the stiffness of a TKA when changing the thickness of tibial inserts. Comparing the stiffness ratios between test constructs demonstrated that the modified PKD test was sensitive to variations in stiffness caused by thicker implants. A significant increase in knee stiffness was observed with as little as a 2mm incremental insert thickness, resulting in nearly twice the stiffness of the TKA, as documented by the increase in log decrement ratios. The lack of impact on implant size or design type suggests that these variables, when the TKA is appropriately sized and the procedure appropriately performed, do not impact stiffness. The ability of the modified PKD test to produce a sensitive and reproducible measure of relative construct stiffness is a promising new tool to help the surgeon in the operating room assess appropriate insert thickness for soft-tissue balancing.

Authors

Institutions

Publication Details

Journal
Surgical Technology Online
Published
2025-03-18
DOI
https://doi.org/10.52198/25.sti.45.os1838
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing Total Knee Arthroplasty Implant Balance with a Passive Knee Drop Test

Stefano A. Bini, Sean B. Sequeira, Michael Dunbar, Joseph P. Weir et al.
Surgical Technology Online
Total Knee Arthroplasty Outcomes
article

Assessing Total Knee Arthroplasty Implant Balance with a Passive Knee Drop Test

Stefano A. Bini, Sean B. Sequeira, Michael Dunbar, Joseph P. Weir, Sally LiArno, Kevin Abbruzzese, Michael A. Mont
article en

Abstract

This study investigated the ability of a modified PKD test to quantify the relative change in the stiffness of a TKA when changing the thickness of tibial inserts. Comparing the stiffness ratios between test constructs demonstrated that the modified PKD test was sensitive to variations in stiffness caused by thicker implants. A significant increase in knee stiffness was observed with as little as a 2mm incremental insert thickness, resulting in nearly twice the stiffness of the TKA, as documented by the increase in log decrement ratios. The lack of impact on implant size or design type suggests that these variables, when the TKA is appropriately sized and the procedure appropriately performed, do not impact stiffness. The ability of the modified PKD test to produce a sensitive and reproducible measure of relative construct stiffness is a promising new tool to help the surgeon in the operating room assess appropriate insert thickness for soft-tissue balancing.

Surgical Technology OnlineVol. 45
Dalhousie University (CA), University of California, San Francisco (US), Sinai Hospital (US), MedStar Union Memorial Hospital (US), Michigan CardioVascular Institute (US), Stryker (United States) (US)
Openalex Percentile: Top 100%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing Total Knee Arthroplasty Implant Balance with a Passive Knee Drop Test — Stefano A. Bini, Sean B. Sequeira, et al. · Surgical Technology Online (2025) | TGRS Research Map | TGRS