Experience Using a New High-Density Polyethylene-Based Porous Orbital Implant: Explorative 1-Year Performance and Safety Results

OBJECTIVES: To describe our experience with a new high-density porous polyethylene orbital implant post-enucleation and evisceration and comment on their performance and safety. METHODS: Patients with an indication of enucleation or evisceration with orbital implantation were included in a prospective study. All patients were implanted with OCULFIT orbital implants (AJL Ophthalmic S.A.) and followed up over 12 months. Anatomical and functional parameters, motility, and aesthetic appearance were evaluated. Patient satisfaction on a scale of 0 (very bad) to 5 (excellent), complications and success rates were reported. RESULTS: Overall, 16 enucleated and 17 eviscerated eyes were analyzed. Orbital implant motility was good for 93.8% and 100% of enucleated and eviscerated patients, respectively. No shortened fornixes were found after external prosthesis placement, and palpebral fissure, orbital volume, and lower eyelid laxity were symmetric with the contralateral eye for the vast majority. The aesthetic appearance was good for 87.5% and 100% of enucleated and eviscerated patients at the last visit with no differences between groups. Excellent satisfaction was reported for 100% and 94.1% of enucleated and eviscerated patients. Anatomical and functional success rates were 78.8% and 81.8%, respectively. No exposure, infection or complications related to surgery were reported during the follow-up. CONCLUSIONS: After 1 year of follow-up, OCULFIT orbital implants provide excellent patient satisfaction and performance in terms of motility and symmetry with the contralateral eye after external prosthesis placement with no complications related to the surgical procedure. No differences between enucleated and eviscerated eyes were found, and aesthetic results were remarkable for both groups. Conclusions should be interpreted with caution due to the small sample size.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2024-11-27
DOI
https://doi.org/10.3390/prosthesis6060101
Citations
1
Primary Topic
Ocular Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experience Using a New High-Density Polyethylene-Based Porous Orbital Implant: Explorative 1-Year Performance and Safety Results

Víctor Sánchez‐Margalet, Mariola Méndez-Muros, Irene Martínez‐Alberquilla, Antonio Manuel Garrido Hermosilla et al.
1 citations
Prosthesis
Ocular Disorders and Treatments
0.55
article

Experience Using a New High-Density Polyethylene-Based Porous Orbital Implant: Explorative 1-Year Performance and Safety Results

Víctor Sánchez‐Margalet, Mariola Méndez-Muros, Irene Martínez‐Alberquilla, Antonio Manuel Garrido Hermosilla, Enrique Rodríguez-de-la-Rúa-Franch, Estanislao Gutiérrez‐Sánchez, María Isabel López, Raquel Monge-Carmona, María Concepción Díaz-Ruiz
article en
1 citations

Abstract

OBJECTIVES: To describe our experience with a new high-density porous polyethylene orbital implant post-enucleation and evisceration and comment on their performance and safety. METHODS: Patients with an indication of enucleation or evisceration with orbital implantation were included in a prospective study. All patients were implanted with OCULFIT orbital implants (AJL Ophthalmic S.A.) and followed up over 12 months. Anatomical and functional parameters, motility, and aesthetic appearance were evaluated. Patient satisfaction on a scale of 0 (very bad) to 5 (excellent), complications and success rates were reported. RESULTS: Overall, 16 enucleated and 17 eviscerated eyes were analyzed. Orbital implant motility was good for 93.8% and 100% of enucleated and eviscerated patients, respectively. No shortened fornixes were found after external prosthesis placement, and palpebral fissure, orbital volume, and lower eyelid laxity were symmetric with the contralateral eye for the vast majority. The aesthetic appearance was good for 87.5% and 100% of enucleated and eviscerated patients at the last visit with no differences between groups. Excellent satisfaction was reported for 100% and 94.1% of enucleated and eviscerated patients. Anatomical and functional success rates were 78.8% and 81.8%, respectively. No exposure, infection or complications related to surgery were reported during the follow-up. CONCLUSIONS: After 1 year of follow-up, OCULFIT orbital implants provide excellent patient satisfaction and performance in terms of motility and symmetry with the contralateral eye after external prosthesis placement with no complications related to the surgical procedure. No differences between enucleated and eviscerated eyes were found, and aesthetic results were remarkable for both groups. Conclusions should be interpreted with caution due to the small sample size.

ProsthesisVol. 6(6)
Universidad Complutense de Madrid (ES), Hospital Universitario Virgen Macarena (ES), Universidad de Sevilla (ES)
Openalex Percentile: Top 24%
Ocular Disorders and Treatments
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.