Effect of Gentamicin-Loaded Calcium Phosphate Coating and Polymeric Coating on the Degradation Properties of Biodegradable Iron-Based Biomaterials

In the past decades, iron has been one of the intensively studied biodegradable metals due to its suitable mechanical properties, but it suffers from slow degradation in a physiological environment and low bioactivity. In this work, the beneficial properties of ceramic and polymer coatings were merged to enhance the corrosion properties and biological compatibility of Fe-based biomaterials. A new bilayer coating for Fe-based biomaterials that speeds up degradation while offering controlled, localized drug release to prevent infections was prepared. In addition, bioactive coatings with an incorporated antibiotic (gentamicin, Ge) were produced to introduce antibacterial properties into the prepared biomaterials and thus increase their bioactivity. The calcium phosphate (CaP) coating layer as well as a bioactive coating layer of CaP doped with gentamicin was electrochemically deposited onto an iron substrate. A layer of poly(ethylene glycol) was subsequently applied to the selection of prepared specimens to create a bilayer ceramic/polymer coating. Electrochemical and immersion corrosion tests revealed that the application of a bilayer coating allowed achieving the desired acceleration of degradation, while the application of only a ceramic coating led to a reduction in the corrosion rate. A slight increase in the corrosion rate was observed for samples with bioactive drug-containing coatings compared to samples with drug-free coatings. Higher viability of human fibroblastic cells cultured in the extracts of the tested samples was noted for samples with a bilayer coating compared to a ceramic coating. The addition of gentamicin in the bioactive coatings had no significant effect on the viability value. Antibacterial tests proved the antibacterial activity of samples with a gentamicin-loaded coating layer against <i>Escherichia coli</i> and <i>Staphylococcus aureus</i> strains. A detailed study of the release of gentamicin from the prepared coatings revealed a different mechanism of drug release from the ceramic and the ceramic/polymer coating. Furthermore, it was found that the drug was released more slowly and uniformly from the bilayer coating. It is therefore possible to adjust the amount and duration of drug release from the bioactive coating by the thickness of the upper polymer layer. Incorporation of an antibiotic in a combined ceramic/polymer coating enabled the creation of a high-performance bioactive coating for Fe bone implants with the possibility to release a drug in the vicinity of the implant in a controlled manner to address the needs of the patient.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2024-11-27
DOI
https://doi.org/10.1021/acsomega.4c06192
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Gentamicin-Loaded Calcium Phosphate Coating and Polymeric Coating on the Degradation Properties of Biodegradable Iron-Based Biomaterials

Jana Shepa, Martina Petráková, Ján Macko, Martin Kožár et al.
ACS Omega
Bone Tissue Engineering Materials
article

Effect of Gentamicin-Loaded Calcium Phosphate Coating and Polymeric Coating on the Degradation Properties of Biodegradable Iron-Based Biomaterials

Jana Shepa, Martina Petráková, Ján Macko, Martin Kožár, Ondrej Petruš, Renáta Oriňáková, Vanda Hajdučková, Radka Gorejová, Matěj Baláž, Tibor Sopčák, Miriam Kupková, Matej Mičušík
article en

Abstract

In the past decades, iron has been one of the intensively studied biodegradable metals due to its suitable mechanical properties, but it suffers from slow degradation in a physiological environment and low bioactivity. In this work, the beneficial properties of ceramic and polymer coatings were merged to enhance the corrosion properties and biological compatibility of Fe-based biomaterials. A new bilayer coating for Fe-based biomaterials that speeds up degradation while offering controlled, localized drug release to prevent infections was prepared. In addition, bioactive coatings with an incorporated antibiotic (gentamicin, Ge) were produced to introduce antibacterial properties into the prepared biomaterials and thus increase their bioactivity. The calcium phosphate (CaP) coating layer as well as a bioactive coating layer of CaP doped with gentamicin was electrochemically deposited onto an iron substrate. A layer of poly(ethylene glycol) was subsequently applied to the selection of prepared specimens to create a bilayer ceramic/polymer coating. Electrochemical and immersion corrosion tests revealed that the application of a bilayer coating allowed achieving the desired acceleration of degradation, while the application of only a ceramic coating led to a reduction in the corrosion rate. A slight increase in the corrosion rate was observed for samples with bioactive drug-containing coatings compared to samples with drug-free coatings. Higher viability of human fibroblastic cells cultured in the extracts of the tested samples was noted for samples with a bilayer coating compared to a ceramic coating. The addition of gentamicin in the bioactive coatings had no significant effect on the viability value. Antibacterial tests proved the antibacterial activity of samples with a gentamicin-loaded coating layer against <i>Escherichia coli</i> and <i>Staphylococcus aureus</i> strains. A detailed study of the release of gentamicin from the prepared coatings revealed a different mechanism of drug release from the ceramic and the ceramic/polymer coating. Furthermore, it was found that the drug was released more slowly and uniformly from the bilayer coating. It is therefore possible to adjust the amount and duration of drug release from the bioactive coating by the thickness of the upper polymer layer. Incorporation of an antibiotic in a combined ceramic/polymer coating enabled the creation of a high-performance bioactive coating for Fe bone implants with the possibility to release a drug in the vicinity of the implant in a controlled manner to address the needs of the patient.

ACS OmegaVol. 9(49)
Tomas Bata University in Zlín (CZ), University of Pavol Jozef Šafárik (SK), Slovak Academy of Sciences (SK), University of Veterinary Medicine in Košice (SK), Institute of Materials Research of the Slovak Academy of Sciences (SK), Institute of Geotechnics of the Slovak Academy of Sciences (SK)
International Visegrad Fund, Agentúra na Podporu Výskumu a Vývoja
Clean water and sanitation
Openalex Percentile: Top 80%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.