Measurement Method for Mixed-Mode S-Parameters of Termination Structure in Differential Communication Line

Bulk current injection (BCI) tests are considered an important method of evaluating the immunity of a differential communication system. Malfunctions during BCI tests are partly caused by common-mode reflection and mode conversion of electronic control units (ECUs). Their characteristics are determined by termination structures (such as connector, enclosure, and ground wiring) and components on a printed circuit board (PCB) housed in ECUs. Conventional measurement methods using current probes cannot separate the characteristics of the termination structures for ECUs on one side because the measurement results include the effects of cable length resonances and reflections at the ECUs. Furthermore, the methods cannot measure mode conversions between the differential and common modes because currently, the current probe measures only the common mode. Thus, we cannot obtain an accurate model of the ECU on one side in the differential communication system. This study proposes a method to measure mixed-mode S-parameters of the termination structures for the ECU on one side using a current probe. We designed the load simulator on the other side to suppress the reflection and mode conversion using matched termination and balanced circuit. Consequently, we measured only the equipment under test (EUT) characteristics without cable length resonances. In addition, we placed two ports on the PCB instead of an IC to measure transmission through the EUT. Subsequently, we measured the characteristics including mode conversions. Furthermore, the effectiveness of this method was verified by SPICE simulation and experiment. In the experiment, experimental and theoretical results were compared considering measurement errors.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Electromagnetic Compatibility
Published
2024-11-27
DOI
https://doi.org/10.1109/temc.2024.3495038
Citations
1
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Method for Mixed-Mode S-Parameters of Termination Structure in Differential Communication Line

Masahiro Yoshida, Yusuke Yano, Jianqing Wang
1 citations
IEEE Transactions on Electromagnetic Compatibility
Power Line Communications and Noise
0.21
article

Measurement Method for Mixed-Mode S-Parameters of Termination Structure in Differential Communication Line

Masahiro Yoshida, Yusuke Yano, Jianqing Wang
article en
1 citations

Abstract

Bulk current injection (BCI) tests are considered an important method of evaluating the immunity of a differential communication system. Malfunctions during BCI tests are partly caused by common-mode reflection and mode conversion of electronic control units (ECUs). Their characteristics are determined by termination structures (such as connector, enclosure, and ground wiring) and components on a printed circuit board (PCB) housed in ECUs. Conventional measurement methods using current probes cannot separate the characteristics of the termination structures for ECUs on one side because the measurement results include the effects of cable length resonances and reflections at the ECUs. Furthermore, the methods cannot measure mode conversions between the differential and common modes because currently, the current probe measures only the common mode. Thus, we cannot obtain an accurate model of the ECU on one side in the differential communication system. This study proposes a method to measure mixed-mode S-parameters of the termination structures for the ECU on one side using a current probe. We designed the load simulator on the other side to suppress the reflection and mode conversion using matched termination and balanced circuit. Consequently, we measured only the equipment under test (EUT) characteristics without cable length resonances. In addition, we placed two ports on the PCB instead of an IC to measure transmission through the EUT. Subsequently, we measured the characteristics including mode conversions. Furthermore, the effectiveness of this method was verified by SPICE simulation and experiment. In the experiment, experimental and theoretical results were compared considering measurement errors.

IEEE Transactions on Electromagnetic CompatibilityVol. 67(2)
Nagoya Institute of Technology (JP)
Openalex Percentile: Top 46%
Power Line Communications and Noise
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement Method for Mixed-Mode S-Parameters of Termination Structure in Differential Communication Line — Masahiro Yoshida, Yusuke Yano, et al. · IEEE Transactions on Electromagnetic Compatibility (2024) | TGRS Research Map | TGRS