Analysis and Reduction of Cogging Torque of Permanent Magnet Synchronous Wind Generators Based on the Magnetic Field Modulation Mechanism

In this paper, a magnetic field modulation model considering the influence of phase angles is established for the analysis and weakening of the cogging torque of the permanent magnet synchronous wind generations. Compared with the existing analytical model, the modulation effect of the magnetic field harmonics and phase angle on the cogging torque components is analyzed in the new model. Firstly, flux density model with phase angle characteristics is derived, and the relationship of the cogging torque and magnetic field harmonic is analyzed using energy method. Then, based on the magnetic modulation mechanism, the impact of the phase angle and magnetic field harmonics on the coupling relationship among cogging torque components is analyzed. All cogging torque components are classified as a combination of multiple positive and negative harmonic components, and the contribution characteristics of the components are determined by the harmonic combination and phase angle characteristics. Based on the finite element model (FEM), the magnetic field modulation model of the cogging torque is proved. On the basis of the conclusions obtained, it is further explained that the suppression mechanism of rotor-step skewing is a mutual complementary effect of the positive components and negative cogging components, and the main harmonic is effectively offset by selecting the seasonable of segment number and skewed angle of rotor. Finally, in order to verify the validity of the analysis method, the no-load line back EMF and cogging torque of optimized prototype is tested, and the experimental results agree well with the FEM results.

Authors

Institutions

Publication Details

Journal
CES Transactions on Electrical Machines and Systems
Published
2024-11-27
DOI
https://doi.org/10.30941/cestems.2024.00040
Citations
1
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Reduction of Cogging Torque of Permanent Magnet Synchronous Wind Generators Based on the Magnetic Field Modulation Mechanism

Yiwen Fan, Chao Liu, Jiakuan Xia, Zixuan Zhang et al.
1 citations
CES Transactions on Electrical Machines and Systems
Electric Motor Design and Analysis
0.21
article

Analysis and Reduction of Cogging Torque of Permanent Magnet Synchronous Wind Generators Based on the Magnetic Field Modulation Mechanism

Yiwen Fan, Chao Liu, Jiakuan Xia, Zixuan Zhang, Zexing Li
article en
1 citations

Abstract

In this paper, a magnetic field modulation model considering the influence of phase angles is established for the analysis and weakening of the cogging torque of the permanent magnet synchronous wind generations. Compared with the existing analytical model, the modulation effect of the magnetic field harmonics and phase angle on the cogging torque components is analyzed in the new model. Firstly, flux density model with phase angle characteristics is derived, and the relationship of the cogging torque and magnetic field harmonic is analyzed using energy method. Then, based on the magnetic modulation mechanism, the impact of the phase angle and magnetic field harmonics on the coupling relationship among cogging torque components is analyzed. All cogging torque components are classified as a combination of multiple positive and negative harmonic components, and the contribution characteristics of the components are determined by the harmonic combination and phase angle characteristics. Based on the finite element model (FEM), the magnetic field modulation model of the cogging torque is proved. On the basis of the conclusions obtained, it is further explained that the suppression mechanism of rotor-step skewing is a mutual complementary effect of the positive components and negative cogging components, and the main harmonic is effectively offset by selecting the seasonable of segment number and skewed angle of rotor. Finally, in order to verify the validity of the analysis method, the no-load line back EMF and cogging torque of optimized prototype is tested, and the experimental results agree well with the FEM results.

CES Transactions on Electrical Machines and SystemsVol. 8(4)
North China Electric Power University (CN), Shenyang University of Technology (CN), State Grid Corporation of China (China) (CN), North China University of Water Resources and Electric Power (CN), Henan Energy & Chemical Industry Group (China) (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 46%
Electric Motor Design and Analysis
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.