Concept of a Diagnostic System for Measuring the Electron Temperature Profile of Plasma from the Intensity of Electron Cyclotron Emission for the TRT Facility

The paper presents a concept of the ECE diagnostic for the TRT facility and estimates the achievable measurement parameters in the baseline scenario. The target spectral region for the diagnostic corresponds to the first harmonic of the ECR frequency in ordinary polarization (O1) and the second harmonic in extraordinary polarization (X2). It is proposed to carry out measurements from the low-field side along two lines of sight: radial and toroidally oblique. The accessible spectral region in terms of the normalized radial coordinate is approximately estimated as –0.9 to 0.9 and –0.1 to 0.9. It is proposed to shape the input wave beam by means of a quasi-optical focusing system that provides a transverse size of the resolved region of approximately 3—5 cm for O1 and 1.2—3 cm for X2. For measurements, it is proposed to use Fourier transform spectrometers with a time resolution of about 10 ms and multichannel heterodyne receivers with a time resolution of about 1 μs. The minimum radial size of the resolved region is estimated to be 3—5 cm for O1 and 2—4 cm for X2, depending on the coordinate.

Authors

Institutions

Publication Details

Journal
Физика плазмы
Published
2024-11-27
DOI
https://doi.org/10.31857/s0367292124040036
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concept of a Diagnostic System for Measuring the Electron Temperature Profile of Plasma from the Intensity of Electron Cyclotron Emission for the TRT Facility

D. Mikhaylova, Н А Соловьев
Физика плазмы
Magnetic confinement fusion research
article

Concept of a Diagnostic System for Measuring the Electron Temperature Profile of Plasma from the Intensity of Electron Cyclotron Emission for the TRT Facility

D. Mikhaylova, Н А Соловьев
article en

Abstract

The paper presents a concept of the ECE diagnostic for the TRT facility and estimates the achievable measurement parameters in the baseline scenario. The target spectral region for the diagnostic corresponds to the first harmonic of the ECR frequency in ordinary polarization (O1) and the second harmonic in extraordinary polarization (X2). It is proposed to carry out measurements from the low-field side along two lines of sight: radial and toroidally oblique. The accessible spectral region in terms of the normalized radial coordinate is approximately estimated as –0.9 to 0.9 and –0.1 to 0.9. It is proposed to shape the input wave beam by means of a quasi-optical focusing system that provides a transverse size of the resolved region of approximately 3—5 cm for O1 and 1.2—3 cm for X2. For measurements, it is proposed to use Fourier transform spectrometers with a time resolution of about 10 ms and multichannel heterodyne receivers with a time resolution of about 1 μs. The minimum radial size of the resolved region is estimated to be 3—5 cm for O1 and 2—4 cm for X2, depending on the coordinate.

Физика плазмыVol. 50(4)
Kurchatov Institute (RU), Prokhorov General Physics Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 94%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Concept of a Diagnostic System for Measuring the Electron Temperature Profile of Plasma from the Intensity of Electron Cyclotron Emission for the TRT Facility — D. Mikhaylova, Н А Соловьев · Физика плазмы (2024) | TGRS Research Map | TGRS