Options for Implementation of IR Thermography Diagnostics in a Tokamak with Reactor Technologies TRT

AbstractOptions for implementing the IR thermography diagnostic system in a TRT facility are considered. Two variants of the optical scheme for measuring the temperature of the first wall and divertor targets are proposed: a wide-angle system combined with two divertor channels and a four-channel viewing system. The optical resolution of both systems and the levels of the collected signal are numerically simulated. On the basis of the calculations performed, conclusions are drawn about the compliance of the systems with the requirements for measuring the temperature of TRT plasma-facing elements. The sources of the temperature measurement error are considered, and the error caused by the reflection of radiation from structural plasma-facing elements by the surface under study is estimated. Calibration issues for IR thermography diagnostics are also discussed.

Authors

Institutions

Publication Details

Journal
Физика плазмы
Published
2024-11-27
DOI
https://doi.org/10.31857/s0367292124040113
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Options for Implementation of IR Thermography Diagnostics in a Tokamak with Reactor Technologies TRT

Medvedev Os, Д. И. Елец, D. L. Bogachev, A. G. Razdobarin et al.
Физика плазмы
Magnetic confinement fusion research
article

Options for Implementation of IR Thermography Diagnostics in a Tokamak with Reactor Technologies TRT

Medvedev Os, Д. И. Елец, D. L. Bogachev, A. G. Razdobarin, L. A. Snigirev, Е. Е. Мухин, Ya. R. Shubin
article en

Abstract

AbstractOptions for implementing the IR thermography diagnostic system in a TRT facility are considered. Two variants of the optical scheme for measuring the temperature of the first wall and divertor targets are proposed: a wide-angle system combined with two divertor channels and a four-channel viewing system. The optical resolution of both systems and the levels of the collected signal are numerically simulated. On the basis of the calculations performed, conclusions are drawn about the compliance of the systems with the requirements for measuring the temperature of TRT plasma-facing elements. The sources of the temperature measurement error are considered, and the error caused by the reflection of radiation from structural plasma-facing elements by the surface under study is estimated. Calibration issues for IR thermography diagnostics are also discussed.

Физика плазмыVol. 50(4)
Ioffe Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 94%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.