Distributionally robust optimal configuration of battery energy storage system considering nodal RoCoF security constraints

The large-scale integration of renewable energy source (RES) exacerbates net load fluctuations, reduces system inertia, limits frequency response capabilities, and leads to uneven spatial distribution of inertia resources. To ensure the economic and safe operation of the system, we propose a distributionally robust optimal configuration scheme of battery energy storage system (BESS) considering nodal RoCoF security constraints to address these issues. First, we describe and model the dynamic frequency response characteristics after disturbances, derive the expressions for the system frequency nadir and maximum nodal RoCoF (MN-RoCoF). Second, we address net load uncertainty using the distributionally robust chance constrained (DRCC) approach and incorporate frequency security constraints into the BESS configuration optimization model, embedding the short-term system operation model into the long-term BESS planning. Then, to tackle the highly nonlinear MN-RoCoF constraint, we propose a divide and conquer-based support vector machine (D&C-SVM), to extract the linear relationship between the BESS virtual inertia constant and MN-RoCoF, reformulating the proposed scheme into a mixed-integer second-order cone programming (MISOCP). Finally, we conducted case studies on the IEEE 39-bus and 118-bus test systems. The results verify that the proposed configuration scheme can ensure that the RoCoF at all nodes remains below 1 Hz/s under the preset disturbances. The proposed D&C-SVM demonstrate 99 % accuracy in managing the nonlinear MN-RoCoF constraint. Moreover, the uncertainty in net load is well managed, with all chance constraints satisfied with a confidence level of over 95 %. • An optimal BESS configuration scheme considering nodal RoCoF security constraints. • Net load uncertainty is addressed using a distributionally robust chance-constrained approach. • Expressions for the system frequency nadir and maximum nodal RoCoF are derived. • A D&C-SVM extracts the linear relationship between BESS virtual inertia and maximum nodal RoCoF.

Authors

Institutions

Publication Details

Journal
Journal of Energy Storage
Published
2024-11-27
DOI
https://doi.org/10.1016/j.est.2024.114707
Citations
2
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Distributionally robust optimal configuration of battery energy storage system considering nodal RoCoF security constraints

Zhigang Wu, Danyang Xu, Lin Guan
2 citations
Journal of Energy Storage
Microgrid Control and Optimization
0.66
article

Distributionally robust optimal configuration of battery energy storage system considering nodal RoCoF security constraints

Zhigang Wu, Danyang Xu, Lin Guan
article en
2 citations

Abstract

The large-scale integration of renewable energy source (RES) exacerbates net load fluctuations, reduces system inertia, limits frequency response capabilities, and leads to uneven spatial distribution of inertia resources. To ensure the economic and safe operation of the system, we propose a distributionally robust optimal configuration scheme of battery energy storage system (BESS) considering nodal RoCoF security constraints to address these issues. First, we describe and model the dynamic frequency response characteristics after disturbances, derive the expressions for the system frequency nadir and maximum nodal RoCoF (MN-RoCoF). Second, we address net load uncertainty using the distributionally robust chance constrained (DRCC) approach and incorporate frequency security constraints into the BESS configuration optimization model, embedding the short-term system operation model into the long-term BESS planning. Then, to tackle the highly nonlinear MN-RoCoF constraint, we propose a divide and conquer-based support vector machine (D&C-SVM), to extract the linear relationship between the BESS virtual inertia constant and MN-RoCoF, reformulating the proposed scheme into a mixed-integer second-order cone programming (MISOCP). Finally, we conducted case studies on the IEEE 39-bus and 118-bus test systems. The results verify that the proposed configuration scheme can ensure that the RoCoF at all nodes remains below 1 Hz/s under the preset disturbances. The proposed D&C-SVM demonstrate 99 % accuracy in managing the nonlinear MN-RoCoF constraint. Moreover, the uncertainty in net load is well managed, with all chance constraints satisfied with a confidence level of over 95 %. • An optimal BESS configuration scheme considering nodal RoCoF security constraints. • Net load uncertainty is addressed using a distributionally robust chance-constrained approach. • Expressions for the system frequency nadir and maximum nodal RoCoF are derived. • A D&C-SVM extracts the linear relationship between BESS virtual inertia and maximum nodal RoCoF.

Journal of Energy StorageVol. 104
South China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 28%
Microgrid Control and Optimization
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.