Residual Pix2Pix networks: streamlining PET/CT imaging process by eliminating CT energy conversion

Attenuation correction of PET data is commonly conducted through the utilization of a secondary imaging technique to produce attenuation maps. The customary approach to attenuation correction, which entails the employment of CT images, necessitates energy conversion. However, the present study introduces a novel deep learning-based method that obviates the requirement for CT images and energy conversion. This study employs a residual Pix2Pix network to generate attenuation-corrected PET images using the 4033 2D PET images of 37 healthy adult brains for train and test. The model, implemented in TensorFlow and Keras, was evaluated by comparing image similarity, intensity correlation, and distribution against CT-AC images using metrics such as PSNR and SSIM for image similarity, while a 2D histogram plotted pixel intensities. Differences in standardized uptake values (SUV) demonstrated the model's efficiency compared to the CTAC method. The residual Pix2Pix demonstrated strong agreement with the CT-based attenuation correction, the proposed network yielding MAE, MSE, PSNR, and MS-SSIM values of 3 × 10<sup>-3</sup>, 2 × 10<sup>-4</sup>, 38.859, and 0.99, respectively. The residual Pix2Pix model's results showed a negligible mean SUV difference of 8 × 10<sup>-4</sup>(P-value = 0.10), indicating its accuracy in PET image correction. The residual Pix2Pix model exhibits high precision with a strong correlation coefficient of R<sup>2</sup> = 0.99 to CT-based methods. The findings indicate that this approach surpasses the conventional method in terms of precision and efficacy. The proposed residual Pix2Pix framework enables accurate and feasible attenuation correction of brain F-FDG PET without CT. However, clinical trials are required to evaluate its clinical performance. The PET images reconstructed by the framework have low errors compared to the accepted test reliability of PET/CT, indicating high quantitative similarity.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2024-11-27
DOI
https://doi.org/10.1088/2057-1976/ad97c2
Citations
2
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residual Pix2Pix networks: streamlining PET/CT imaging process by eliminating CT energy conversion

Alireza Sadremomtaz, Sara Ghanbari
2 citations
Biomedical Physics & Engineering Express
Radiomics and Machine Learning in Medical Imaging
0.81
article

Residual Pix2Pix networks: streamlining PET/CT imaging process by eliminating CT energy conversion

Alireza Sadremomtaz, Sara Ghanbari
article en
2 citations

Abstract

Attenuation correction of PET data is commonly conducted through the utilization of a secondary imaging technique to produce attenuation maps. The customary approach to attenuation correction, which entails the employment of CT images, necessitates energy conversion. However, the present study introduces a novel deep learning-based method that obviates the requirement for CT images and energy conversion. This study employs a residual Pix2Pix network to generate attenuation-corrected PET images using the 4033 2D PET images of 37 healthy adult brains for train and test. The model, implemented in TensorFlow and Keras, was evaluated by comparing image similarity, intensity correlation, and distribution against CT-AC images using metrics such as PSNR and SSIM for image similarity, while a 2D histogram plotted pixel intensities. Differences in standardized uptake values (SUV) demonstrated the model's efficiency compared to the CTAC method. The residual Pix2Pix demonstrated strong agreement with the CT-based attenuation correction, the proposed network yielding MAE, MSE, PSNR, and MS-SSIM values of 3 × 10<sup>-3</sup>, 2 × 10<sup>-4</sup>, 38.859, and 0.99, respectively. The residual Pix2Pix model's results showed a negligible mean SUV difference of 8 × 10<sup>-4</sup>(P-value = 0.10), indicating its accuracy in PET image correction. The residual Pix2Pix model exhibits high precision with a strong correlation coefficient of R<sup>2</sup> = 0.99 to CT-based methods. The findings indicate that this approach surpasses the conventional method in terms of precision and efficacy. The proposed residual Pix2Pix framework enables accurate and feasible attenuation correction of brain F-FDG PET without CT. However, clinical trials are required to evaluate its clinical performance. The PET images reconstructed by the framework have low errors compared to the accepted test reliability of PET/CT, indicating high quantitative similarity.

Biomedical Physics & Engineering ExpressVol. 11(1)
University of Guilan (IR)
Affordable and clean energy
Openalex Percentile: Top 24%
Radiomics and Machine Learning in Medical Imaging
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.