Synthesis and Characterization of hematoxylin biomolecule-doped polymeric nanocomposite film and evaluation of its performance as Low gamma-ray Dosimeter applied to medical diagnosis

Currently, gamma dosimetry linked to public health is gaining more and more importance in the field of medical diagnosis. The use of different dyes, sensitive to radiation dose intensity, incorporated into different polymer biofilms has shown promising avenues for radiation dosimetry. Accordingly, the hematoxylin biomolecule as a low-ray dose sensitive dye will be integrated into a polyvinyl alcohol (PVA) polymeric host film. Direct detection of hematoxylin color change after irradiation with different g-ray doses (2, 4, 10, and 20 mGy) was apparent allowing visual estimation of radiation dose. The impact of the different radiation exposures has been evaluated via FTIR, UV, optical, colorimetric, and SEM analysis. FTIR investigation revealed an obvious chemical change with increased doses. SEM investigation showed significant morphological alteration of PVA/HX films following radiation exposure. Moreover, the produced PVA/HX films displayed good pre- and post-irradiation stability in both dark and light conditions. Furthermore, response behaviors, deduced from the different characterizations, according to increasing -ray intensities have been recorded to assess their dosimetric potential for the routine -irradiation process. Indeed, the UV-Vis response curve demonstrated a linear rise in absorbance as radiation doses increased (R = 0.992). Similarly, the different varied parameters in the colorimetry study increased linearly with increasing g-ray doses. The proposed novel dosimeter designed in nanoscale composite film might consequently offer an effective alternative for accurate and direct assessment of -ray low doses finding promising use in various medical applications.

Authors

Institutions

Publication Details

Journal
Egyptian Journal of Chemistry
Published
2024-11-27
DOI
https://doi.org/10.21608/ejchem.2024.325402.10565
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis and Characterization of hematoxylin biomolecule-doped polymeric nanocomposite film and evaluation of its performance as Low gamma-ray Dosimeter applied to medical diagnosis

Saleh Alashrah, Yassine El Ghoul, Chiraz Ammar
1 citations
Egyptian Journal of Chemistry
Medical Imaging Techniques and Applications
0.40
article

Synthesis and Characterization of hematoxylin biomolecule-doped polymeric nanocomposite film and evaluation of its performance as Low gamma-ray Dosimeter applied to medical diagnosis

Saleh Alashrah, Yassine El Ghoul, Chiraz Ammar
article en
1 citations

Abstract

Currently, gamma dosimetry linked to public health is gaining more and more importance in the field of medical diagnosis. The use of different dyes, sensitive to radiation dose intensity, incorporated into different polymer biofilms has shown promising avenues for radiation dosimetry. Accordingly, the hematoxylin biomolecule as a low-ray dose sensitive dye will be integrated into a polyvinyl alcohol (PVA) polymeric host film. Direct detection of hematoxylin color change after irradiation with different g-ray doses (2, 4, 10, and 20 mGy) was apparent allowing visual estimation of radiation dose. The impact of the different radiation exposures has been evaluated via FTIR, UV, optical, colorimetric, and SEM analysis. FTIR investigation revealed an obvious chemical change with increased doses. SEM investigation showed significant morphological alteration of PVA/HX films following radiation exposure. Moreover, the produced PVA/HX films displayed good pre- and post-irradiation stability in both dark and light conditions. Furthermore, response behaviors, deduced from the different characterizations, according to increasing -ray intensities have been recorded to assess their dosimetric potential for the routine -irradiation process. Indeed, the UV-Vis response curve demonstrated a linear rise in absorbance as radiation doses increased (R = 0.992). Similarly, the different varied parameters in the colorimetry study increased linearly with increasing g-ray doses. The proposed novel dosimeter designed in nanoscale composite film might consequently offer an effective alternative for accurate and direct assessment of -ray low doses finding promising use in various medical applications.

Egyptian Journal of ChemistryVol. 67(13)
Qassim University (SA)
Openalex Percentile: Top 32%
Medical Imaging Techniques and Applications
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synthesis and Characterization of hematoxylin biomolecule-doped polymeric nanocomposite film and evaluation of its performance as Low gamma-ray Dosimeter applied to medical diagnosis — Saleh Alashrah, Yassine El Ghoul, et al. · Egyptian Journal of Chemistry (2024) | TGRS Research Map | TGRS