EVALUATION OF THE ZYGOMATIC IMPLANT PLACEMENT USING 3D SURGICAL GUIDE

Background: Zygomatic implants provide as an alternative to extensive grafting techniques for addressing atrophic posterior maxilla. The placement of zygomatic implants is technically complex, often leading to severe problems and various prosthetic difficulties due to inaccurate positioning. Virtual surgical planning enhances the precise placing of zygomatic implants and promotes advantageous prosthetic results.Aim of the study: This study was conducted with the aim of evaluating the three-dimensional morphological and functional accuracy of virtual surgical planning (VSP) guided zygomatic implant placement.Materials and methods: Zygomatic implants were utilized to support the posterior areas of the rehabilitation. The implant was placed by transferring the preoperatively planned position to the surgical field utilizing cone beam computed tomography (CBCT) and an implant planning software to create a 3D-printed surgical guide. A three-dimensional radiographic examination was carried out immediately to assess the precision of the virtual surgical planning.Results: A total of eight implants in this study. In all patients two zygomatic implants were inserted, one on each side. The mean linear coronal deviations between virtually planned and actually placed implants was 1.49 ± 0.53, which ranged from 1.01 – 2.90. The mean linear apical deviations between virtually planned and actually placed implants was 2.08 ± 0.55, which ranged from 2.89 – 6.89. The mean angular deviations between virtually planned and actually placed implants was 2.08 ± 0.55, which ranged from 2.89 – 6.89. Keywords: zygomatic implant, virtual planning accuracy, 3D printing, surgical guide.Running Title: Zygomatic implant placement using surgical guide.

Authors

Institutions

Publication Details

Journal
Alexandria Dental Journal
Published
2024-11-20
DOI
https://doi.org/10.21608/adjalexu.2024.323270.1539
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF THE ZYGOMATIC IMPLANT PLACEMENT USING 3D SURGICAL GUIDE

Mervat Khalil, Adham ElAshwah, Ahmed Mahmoud Qassem, Mohamed Shokry
Alexandria Dental Journal
Dental Implant Techniques and Outcomes
article

EVALUATION OF THE ZYGOMATIC IMPLANT PLACEMENT USING 3D SURGICAL GUIDE

Mervat Khalil, Adham ElAshwah, Ahmed Mahmoud Qassem, Mohamed Shokry
article en

Abstract

Background: Zygomatic implants provide as an alternative to extensive grafting techniques for addressing atrophic posterior maxilla. The placement of zygomatic implants is technically complex, often leading to severe problems and various prosthetic difficulties due to inaccurate positioning. Virtual surgical planning enhances the precise placing of zygomatic implants and promotes advantageous prosthetic results.Aim of the study: This study was conducted with the aim of evaluating the three-dimensional morphological and functional accuracy of virtual surgical planning (VSP) guided zygomatic implant placement.Materials and methods: Zygomatic implants were utilized to support the posterior areas of the rehabilitation. The implant was placed by transferring the preoperatively planned position to the surgical field utilizing cone beam computed tomography (CBCT) and an implant planning software to create a 3D-printed surgical guide. A three-dimensional radiographic examination was carried out immediately to assess the precision of the virtual surgical planning.Results: A total of eight implants in this study. In all patients two zygomatic implants were inserted, one on each side. The mean linear coronal deviations between virtually planned and actually placed implants was 1.49 ± 0.53, which ranged from 1.01 – 2.90. The mean linear apical deviations between virtually planned and actually placed implants was 2.08 ± 0.55, which ranged from 2.89 – 6.89. The mean angular deviations between virtually planned and actually placed implants was 2.08 ± 0.55, which ranged from 2.89 – 6.89. Keywords: zygomatic implant, virtual planning accuracy, 3D printing, surgical guide.Running Title: Zygomatic implant placement using surgical guide.

Alexandria Dental JournalVol. 0(0)
Alexandria University (EG)
Gender equality
Openalex Percentile: Top 67%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.