Prenatal Prediction of Fetal Lung Maturity Using 3D Lung Volume, Lung-to-Liver Intensity Ratio Tissue Histogram and Pulmonary Artery Doppler Indices

Background: Fetal lung maturity assessment is regarded as the most critical factor for identifying the optimal delivery time. A noninvasive sonographic technique is necessary to evaluate fetal lung development, as amniocentesis is an invasive method that result in real hazard to pregnancy.Aim of the study: This study aimed to predict maturity of fetal lung utilizing 3D lung volume ultrasound, lung to liver intensity ratio, and pulmonary artery Doppler indices measurement.Patients and Methods: Three-dimensional [3D] ultrasound [3DUS] has been performed to determine the fetal lung volume [FLV] then fetal lung-to-liver intensity ratio [FLLIR] [tissue histogram] and the main pulmonary artery doppler parameters [MPA]; acceleration time-to-ejection timer ratio [At/Et], pulsatility index [PI] and resistive index [RI] have been performed to two hundred pregnant females from thirty-two to forty weeks age at pregnancy during one week from delivery. Results: Of 200 fetuses investigated, 113 cases [56.5%] have been investigated with respiratory distress syndrome. The MPA RI and PI were significantly greater in fetuses investigated with respiratory distress syndrome comparing with those with no [2.6± 0.3 and 0.9±0.05 vs. 1.9±0.3 and 0.8±0.2, p-value less than 0.001, less than 0.001 respectively]. MPA At/Et was significantly lesser for fetuses with RDS than fetuses without RDS [0.2±0.1 vs. 0.3±0.1 respectively, p-value less than 0.001]. FLLIR was significantly lesser in RDS positive group comparing with RDS negative group [0.9±0.2 versus 1.3±0.3 respectively, p-value less than 0.001] and FLV was significantly smaller in fetuses with respiratory distress syndrome comparing with those with no [31.5±2.5 vs. 38.1±2.8; p-value less than 0.001].Conclusion: The utilization of main pulmonary artery Doppler indices, together with mean fetal lung volume and FLLIR for assessing fetal lung is a quick noninvasive accurate technique for estimate of neonatal FLM and respiratory distress syndrome.

Authors

Institutions

Publication Details

Journal
International Journal of Medical Arts
Published
2024-11-24
DOI
https://doi.org/10.21608/ijma.2024.317254.2026
Primary Topic
Congenital Diaphragmatic Hernia Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prenatal Prediction of Fetal Lung Maturity Using 3D Lung Volume, Lung-to-Liver Intensity Ratio Tissue Histogram and Pulmonary Artery Doppler Indices

Mohamed Sabry Aboelnasr, Shaimaa Abdel-hamid Hassanein, Ahmed Tharwat, Aml Shafik Omar et al.
International Journal of Medical Arts
Congenital Diaphragmatic Hernia Studies
article

Prenatal Prediction of Fetal Lung Maturity Using 3D Lung Volume, Lung-to-Liver Intensity Ratio Tissue Histogram and Pulmonary Artery Doppler Indices

Mohamed Sabry Aboelnasr, Shaimaa Abdel-hamid Hassanein, Ahmed Tharwat, Aml Shafik Omar, Haitham S. Hamza, Wael Gaber Eldamaty
article en

Abstract

Background: Fetal lung maturity assessment is regarded as the most critical factor for identifying the optimal delivery time. A noninvasive sonographic technique is necessary to evaluate fetal lung development, as amniocentesis is an invasive method that result in real hazard to pregnancy.Aim of the study: This study aimed to predict maturity of fetal lung utilizing 3D lung volume ultrasound, lung to liver intensity ratio, and pulmonary artery Doppler indices measurement.Patients and Methods: Three-dimensional [3D] ultrasound [3DUS] has been performed to determine the fetal lung volume [FLV] then fetal lung-to-liver intensity ratio [FLLIR] [tissue histogram] and the main pulmonary artery doppler parameters [MPA]; acceleration time-to-ejection timer ratio [At/Et], pulsatility index [PI] and resistive index [RI] have been performed to two hundred pregnant females from thirty-two to forty weeks age at pregnancy during one week from delivery. Results: Of 200 fetuses investigated, 113 cases [56.5%] have been investigated with respiratory distress syndrome. The MPA RI and PI were significantly greater in fetuses investigated with respiratory distress syndrome comparing with those with no [2.6± 0.3 and 0.9±0.05 vs. 1.9±0.3 and 0.8±0.2, p-value less than 0.001, less than 0.001 respectively]. MPA At/Et was significantly lesser for fetuses with RDS than fetuses without RDS [0.2±0.1 vs. 0.3±0.1 respectively, p-value less than 0.001]. FLLIR was significantly lesser in RDS positive group comparing with RDS negative group [0.9±0.2 versus 1.3±0.3 respectively, p-value less than 0.001] and FLV was significantly smaller in fetuses with respiratory distress syndrome comparing with those with no [31.5±2.5 vs. 38.1±2.8; p-value less than 0.001].Conclusion: The utilization of main pulmonary artery Doppler indices, together with mean fetal lung volume and FLLIR for assessing fetal lung is a quick noninvasive accurate technique for estimate of neonatal FLM and respiratory distress syndrome.

International Journal of Medical ArtsVol. 0(0)
Menoufia University (EG)
Zero hunger
Openalex Percentile: Top 59%
Congenital Diaphragmatic Hernia Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.