EFFECT OF TWO DIFFERENT HEAT-TREATED MINIMALLY INVASIVE NICKELـTITANIUM ROTARY FILE SYSTEMS ON ROOT FRACTURE RESISTANCE (AN IN VITRO STUDY)

Background: NickelـTitanium rotary files can induce dentinal cracks on the root canal walls and over time functional load can develop and cause vertical root fracture.Aim: To evaluate the vertical root fracture (VRF) resistance of endodontically treated teeth prepared with two different heatـtreated minimally invasive rotating file systems.Materials and methods: 45 human mature mandibular first molars were selected & decoronated followed by sectioning of distal roots, obtaining mesial roots 14 mm long. The mesial roots were mounted in resin molds and randomly assigned to three equal groups; one negative control group (n=15) and two experimental groups (each n=15) according to the file system used. Group 1 ـــinstrumented by HyFlex EDM, Group 2 ـــinstrumented by Protaper Ultimate, Group 3 ـــnegative control (no instrumentation). Single cone obturation was performed with resin sealer and guttaـpercha. Subsequently, all specimens were subjected to vertical compressive load using the universal testing machine to record the force (N) needed until root fracture. Data were statistically analyzed.Results: The control group showed the greatest fracture resistance, followed by HyFlex EDM and Protaper Ultimate. No statistical difference was noted between the two tested groups (P =0.055) and between the control and HyFlex EDM (P =0.295). In contrast, a statistically substantial difference was observed between the control and the Protaper Ultimate (P =0.001). Conclusions: Minimally invasive heat-treated files could preserve more pericervical dentin (PCD), enhancing fracture resistance. HyFlex EDM files maintain tooth strength better than Protaper Ultimate system, with no significant difference.

Authors

Institutions

Publication Details

Journal
Alexandria Dental Journal
Published
2024-11-20
DOI
https://doi.org/10.21608/adjalexu.2024.300432.1517
Primary Topic
Shoulder and Clavicle Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EFFECT OF TWO DIFFERENT HEAT-TREATED MINIMALLY INVASIVE NICKELـTITANIUM ROTARY FILE SYSTEMS ON ROOT FRACTURE RESISTANCE (AN IN VITRO STUDY)

Nayera Mokhless, Nihal Leheta, M.F.M. Ibrahim
1 links
Alexandria Dental Journal
Shoulder and Clavicle Injuries
article

EFFECT OF TWO DIFFERENT HEAT-TREATED MINIMALLY INVASIVE NICKELـTITANIUM ROTARY FILE SYSTEMS ON ROOT FRACTURE RESISTANCE (AN IN VITRO STUDY)

Nayera Mokhless, Nihal Leheta, M.F.M. Ibrahim
article en

Abstract

Background: NickelـTitanium rotary files can induce dentinal cracks on the root canal walls and over time functional load can develop and cause vertical root fracture.Aim: To evaluate the vertical root fracture (VRF) resistance of endodontically treated teeth prepared with two different heatـtreated minimally invasive rotating file systems.Materials and methods: 45 human mature mandibular first molars were selected & decoronated followed by sectioning of distal roots, obtaining mesial roots 14 mm long. The mesial roots were mounted in resin molds and randomly assigned to three equal groups; one negative control group (n=15) and two experimental groups (each n=15) according to the file system used. Group 1 ـــinstrumented by HyFlex EDM, Group 2 ـــinstrumented by Protaper Ultimate, Group 3 ـــnegative control (no instrumentation). Single cone obturation was performed with resin sealer and guttaـpercha. Subsequently, all specimens were subjected to vertical compressive load using the universal testing machine to record the force (N) needed until root fracture. Data were statistically analyzed.Results: The control group showed the greatest fracture resistance, followed by HyFlex EDM and Protaper Ultimate. No statistical difference was noted between the two tested groups (P =0.055) and between the control and HyFlex EDM (P =0.295). In contrast, a statistically substantial difference was observed between the control and the Protaper Ultimate (P =0.001). Conclusions: Minimally invasive heat-treated files could preserve more pericervical dentin (PCD), enhancing fracture resistance. HyFlex EDM files maintain tooth strength better than Protaper Ultimate system, with no significant difference.

Alexandria Dental JournalVol. 0(0)
Alexandria University (EG)
Openalex Percentile: Top 68%
Shoulder and Clavicle Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.