Assessing scleral thickness in patients with POAG and myopia by using OCT

BackgroundThe aim of the study is to utilize swept-source OCT for imaging the rear sclera near the ONH, calculating the thickness of the SL and lamina, and examining how these measurements correspond to various metrics.DesignCross-sectional design with a prospective approach.Materials and methodsThe study included 96 glaucoma patients and 39 control subjects, all with axial lengths greater than 23 mm. Swept-source OCT was used to visualize the subfoveal and ONH regions. Thicknesses of SL and lamina were then calculated from the "B-scan" visuals collected. In order to confirm the consistency of the calculation, "intraclass correlation coefficients" were computed from specific "B-scans". The study compared the thickness of the SL and lamina in subjects with NTG to those with POAG. A "Pearson correlation" was conducted to analyze the connections between the thickness of the SL and lamina with various ocular parameters.ResultsSwept-source OCT enabled the measurement of posterior SL thickness in 65.9% and laminar thickness in 89.8% of the subjects. The consistency of measurements taken by different observers and by the same observer varied from moderate to excellent. There was a notable variation among the NTG and POAG sets in terms of subfoveal SL thickness, with measurements of 680.84 ± 170.60 mm and 486.55 ± 125.21 mm, respectively. The connection among subfoveal SL thickness and axial-length was discovered to be negative in subjects with NTG, but this was not observed in subjects with POAG. The variation in connection among the 2 subject groups was statistically important (r [ L0.687, P < 0.002).Conclusions"Swept-source OCT" identified variations in posterior SL thickness between NTG and POAG eyes. The subfoveal scleral thickness showed a negative association with axial-length, particularly in eyes with normal-tension glaucoma.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2024-11-26
DOI
https://doi.org/10.1177/11206721241302115
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing scleral thickness in patients with POAG and myopia by using OCT

Asadullah Jatoi
European Journal of Ophthalmology
Glaucoma and retinal disorders
article

Assessing scleral thickness in patients with POAG and myopia by using OCT

Asadullah Jatoi
article en

Abstract

BackgroundThe aim of the study is to utilize swept-source OCT for imaging the rear sclera near the ONH, calculating the thickness of the SL and lamina, and examining how these measurements correspond to various metrics.DesignCross-sectional design with a prospective approach.Materials and methodsThe study included 96 glaucoma patients and 39 control subjects, all with axial lengths greater than 23 mm. Swept-source OCT was used to visualize the subfoveal and ONH regions. Thicknesses of SL and lamina were then calculated from the "B-scan" visuals collected. In order to confirm the consistency of the calculation, "intraclass correlation coefficients" were computed from specific "B-scans". The study compared the thickness of the SL and lamina in subjects with NTG to those with POAG. A "Pearson correlation" was conducted to analyze the connections between the thickness of the SL and lamina with various ocular parameters.ResultsSwept-source OCT enabled the measurement of posterior SL thickness in 65.9% and laminar thickness in 89.8% of the subjects. The consistency of measurements taken by different observers and by the same observer varied from moderate to excellent. There was a notable variation among the NTG and POAG sets in terms of subfoveal SL thickness, with measurements of 680.84 ± 170.60 mm and 486.55 ± 125.21 mm, respectively. The connection among subfoveal SL thickness and axial-length was discovered to be negative in subjects with NTG, but this was not observed in subjects with POAG. The variation in connection among the 2 subject groups was statistically important (r [ L0.687, P < 0.002).Conclusions"Swept-source OCT" identified variations in posterior SL thickness between NTG and POAG eyes. The subfoveal scleral thickness showed a negative association with axial-length, particularly in eyes with normal-tension glaucoma.

European Journal of OphthalmologyVol. 35(4)
Liaquat University of Medical & Health Sciences (PK)
Openalex Percentile: Top 65%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.