Integrated seismic and energetic rehabilitation of existing buildings based on the tuned mass damper concept

• Novel integrated seismic and energetic rehabilitation technique based on the tuned mass damper concept. • Integrated seismic and energy retrofit exploiting the roof as structural element. • Assessment of the tuned mass damper and tuned mass damper inerter for existing buildings. • Increasing building energy efficiency with cool, photovoltaic and green roof. • Methodology and procedure to select the optimal intervention among the integrated seismic and energetic retrofits. The preservation of the existing building heritage to guarantee structural integrity is a paramount concern. At the same time, energy rehabilitation to enhance existing buildings efficiency is a key issue. In recent years the scientific community is making efforts to explore integrated seismic and energy retrofitting techniques combining them into a single assessment also pointing to a sustainable design. The paper explores for the first time the implementation of novel integrated seismic and energetic rehabilitation techniques drawing upon the concept of tuned mass damper (TMD). The structural solutions proposed implement the TMD concept on the roof, disconnected and isolated from the substructure, by means of different approaches realizing a non-conventional TMD, a TMD with large mass ratio and a tuned mass damper inerter (TMDI). The seismic retrofit interventions are seamlessly integrated with suitable energy retrofit strategies exploiting the same element realizing a cool roof, a photovoltaic roof, a green roof. A straight methodology for the implementation and design of the integrated interventions and a new procedure to select the optimal intervention is proposed. The methodology is exemplified on a case study of a typical reinforced concrete building. The results show that the realization of a lightweight photovoltaic roof employing a TMDI represents the optimal intervention, minimizing simultaneously interstory drifts and building primary energy consumption. However, it is highlighted that a different calibration of the weights given to the seismic and energy retrofits can affect the optimal choice.

Authors

Publication Details

Journal
Results in Engineering
Published
2024-11-27
DOI
https://doi.org/10.1016/j.rineng.2024.103552
Citations
4
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated seismic and energetic rehabilitation of existing buildings based on the tuned mass damper concept

Filippo Busato, Michela Basili, Maurizio De Angelis
4 citations
Results in Engineering
Vibration Control and Rheological Fluids
1.04
article

Integrated seismic and energetic rehabilitation of existing buildings based on the tuned mass damper concept

Filippo Busato, Michela Basili, Maurizio De Angelis
article en
4 citations

Abstract

• Novel integrated seismic and energetic rehabilitation technique based on the tuned mass damper concept. • Integrated seismic and energy retrofit exploiting the roof as structural element. • Assessment of the tuned mass damper and tuned mass damper inerter for existing buildings. • Increasing building energy efficiency with cool, photovoltaic and green roof. • Methodology and procedure to select the optimal intervention among the integrated seismic and energetic retrofits. The preservation of the existing building heritage to guarantee structural integrity is a paramount concern. At the same time, energy rehabilitation to enhance existing buildings efficiency is a key issue. In recent years the scientific community is making efforts to explore integrated seismic and energy retrofitting techniques combining them into a single assessment also pointing to a sustainable design. The paper explores for the first time the implementation of novel integrated seismic and energetic rehabilitation techniques drawing upon the concept of tuned mass damper (TMD). The structural solutions proposed implement the TMD concept on the roof, disconnected and isolated from the substructure, by means of different approaches realizing a non-conventional TMD, a TMD with large mass ratio and a tuned mass damper inerter (TMDI). The seismic retrofit interventions are seamlessly integrated with suitable energy retrofit strategies exploiting the same element realizing a cool roof, a photovoltaic roof, a green roof. A straight methodology for the implementation and design of the integrated interventions and a new procedure to select the optimal intervention is proposed. The methodology is exemplified on a case study of a typical reinforced concrete building. The results show that the realization of a lightweight photovoltaic roof employing a TMDI represents the optimal intervention, minimizing simultaneously interstory drifts and building primary energy consumption. However, it is highlighted that a different calibration of the weights given to the seismic and energy retrofits can affect the optimal choice.

Results in EngineeringVol. 24
Sustainable cities and communities
Openalex Percentile: Top 25%
Vibration Control and Rheological Fluids
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.