Comparison of the biomechanical effect of distal implants placed at different angles in the all-on-four technique: A nonlinear finite element analysis
As the angle of insertion of the implant into the bone increases, the biomechanical stress value on the implant and abutment also increases. Among the models, the lowest von Mises stress values on the implant and abutment were measured in model I and model II. Models with low stress values can be recommended for patients with clinical conditions and biomechanical risk factors.
Authors
- Aylin Sipahi Çalış (ORCID: https://orcid.org/0000-0003-3206-9697)
- Osman Koç (ORCID: https://orcid.org/0000-0002-2682-8282)
- Yıldız Ünüvar
Institutions
- Yıldız Technical University (TR)
- Ege University (TR)
Publication Details
- Journal
- Journal of Stomatology Oral and Maxillofacial Surgery
- Published
- 2024-11-27
- DOI
- https://doi.org/10.1016/j.jormas.2024.102157
- Citations
- 3
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 1.72
Funders
- Ege Üniversitesi