131I Accumulation Due to an Intrauterine Device in a Papillary Thyroid Carcinoma Patient

A 46-year-old woman underwent 131 I radiotherapy following thyroidectomy for papillary thyroid carcinoma. Posttherapeutic 131 I scintigraphy was performed 4 days later. Both attenuation-corrected and non-attenuation-corrected 131 I tomography images elucidated an intrauterine device with avid 131 I uptake in her uterus. This case illustrated that an intrauterine device should be considered as a potential cause of false-positive results in posttherapeutic 131 I scintigraphy, highlighting the need for accurate image interpretation to avoid unnecessary treatment.

Authors

Institutions

Publication Details

Journal
Clinical Nuclear Medicine
Published
2024-11-27
DOI
https://doi.org/10.1097/rlu.0000000000005597
Citations
5
Primary Topic
Medical Imaging and Pathology Studies
Type
article
Field-Weighted Citation Impact
2.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

131I Accumulation Due to an Intrauterine Device in a Papillary Thyroid Carcinoma Patient

Yuan Feng, Xiaoli Lan, Xiao Zhang
5 citations
Clinical Nuclear Medicine
Medical Imaging and Pathology Studies
2.09
article

131I Accumulation Due to an Intrauterine Device in a Papillary Thyroid Carcinoma Patient

Yuan Feng, Xiaoli Lan, Xiao Zhang
article en
5 citations

Abstract

A 46-year-old woman underwent 131 I radiotherapy following thyroidectomy for papillary thyroid carcinoma. Posttherapeutic 131 I scintigraphy was performed 4 days later. Both attenuation-corrected and non-attenuation-corrected 131 I tomography images elucidated an intrauterine device with avid 131 I uptake in her uterus. This case illustrated that an intrauterine device should be considered as a potential cause of false-positive results in posttherapeutic 131 I scintigraphy, highlighting the need for accurate image interpretation to avoid unnecessary treatment.

Clinical Nuclear MedicineVol. 50(4)
Union Hospital (HK), State Key Laboratory of Information Engineering in Surveying Mapping and Remote Sensing (CN), Union Hospital (CN), Huazhong University of Science and Technology (CN)
Good health and well-being
Openalex Percentile: Top 12%
Medical Imaging and Pathology Studies
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.